Installation
RTCSmp
Built-In Module-Line Dual/Quad Cooktops
Part Number 4532415 12/14
Page 15
4.2.2
Installation Clearance
a
Cable Bend /
Connection Clearance
(minimum)
b
Air Exhaust/
Intake Clearance
(minimum)
c
Clearance
(minimum)
Induction
Generator
127mm / 5”
40mm / 1.57”
10mm / 0.39”
(sides, top,
and bottom)
Control
Unit
70mm / 2.75”
--
38mm / 1.5”
(for service
interface)
Coil Carrier
Sheet
127mm / 5”
--
100mm /
3.94”
(below coil
carrier sheet)
Operation
Unit
12.7mm / 0.5“
--
--
4.3
Induction Generator
IMPORTANT
The maximum operating temperature for the induction unit must not exceed 104
F (40
C).
Buildup of hot exhaust air around the induction unit will cause the unit to reduce power or to switch-off.
Recommended
: At an appropriate location on the cabinet, install an exhaust fan to force hot air out the
cabinet and away from the induction unit. Consult an electrical or installation expert for the most
appropriate location to install a cabinet exhaust fan.
Recommended
: Filter the intake air with an air intake filter. Kitchen air often contains grease laden
vapors. Grease deposits inside the generator may cause overheating. Failure to provide clean fresh
cooling air may void warranty.
NOTE: Additional fans and cooling controls are the responsibility of the customer and installer.
Refer to the data in section
3.5 Operating Conditions
.
a
c
b
b
c
c
c
c
a
a
a