Installation
RTCSmp
Built-In
Module-Line Dual/Quad Cooktops
16
Part Number 4532415 12/14
4.3.1
Location
It is possible to install the induction unit near heat-producing or steam-producing equipment such as an
oven or a fryer. However, use an external fan to pull hot air, greasy fume, and moisture away from the
induction unit.
If the generator is installed directly under the induction coil or in the same chamber of as the coil, ensure
the ventilation system will keep the ambient temperature below 104
F (40
C).
Keep all combustible materials, vapors or liquids away from the generator.
Ensure the installed location of the generator is safe from any ingress of liquid into the immediate
vicinity.
The generator can be mounted in any orientation as long as:
o
the equipment and cable connections are accessible for maintenance and service.
o
the fresh air intake and exhaust air outlet are not blocked.
4.3.2
Ventilation
Maximum air flow of the fan is 70.63 cfm (120 m
3
per hour) and therefore a minimum opening of 10.08
sq. in. (6500 mm
2
) is required around the fresh air intake.
An optimal air circulation and air flow must not be restricted by installation.
The in-take air and exhaust air must not mix.
Recommended
: To avoid build-up of hot exhaust air inside
the cabinet, use a fan to draw the exhaust air out, or provide a separate exhaust air plenum. Note that
additional fans and cooling controls are the responsibility of the customer and installer.
4.3.3
Dimensions
Models: MO DU 7000/ 10000 MO QU14000/ 20000/ 21000/ 24000
23.62” (600 mm)
min 1.57” (40 mm)
min 5” (127mm)
23.62” (600 mm)
14.17”
(360 mm)
6.02” (153 mm)
2.58”
(65.5 mm)
6.81” (173 mm)
6.22”
(158 mm)
3.98”
(101 mm)
3.98”
(101 mm)
1.02”
(26 mm)
mains connection
CAN/BUS
air exhaust
clearance
air supply
coil
connection
field 1+2
air supply
air exhaust
1.57”
(40 mm)
fan
cable bend
clearance