background image

I n s t a l l a t i o n   a n d   O p e r a t i o n   M a n u a l  

  Series 

 

RN8450G RNL8450G RNB8450G RNLB8450G 

RN8900G RNL8900G RNB8900G RNLB8900G 

 

G a s   C o o k t o p s  

( 4 5 0 m m   W i d e   H o b s )

 

Date Purchased 

Serial Number 

Dealer 

 

Service Provider 

 

232778-9 

 

For use in GB & IE 

Summary of Contents for RNB8450G

Page 1: ...d O p e r a t i o n M a n u a l Series RN8450G RNL8450G RNB8450G RNLB8450G RN8900G RNL8900G RNB8900G RNLB8900G Gas Cooktops 4 5 0 m m W i d e H o b s Date Purchased Serial Number Dealer Service Provid...

Page 2: ...ares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 14...

Page 3: ...ts Unpacking Location Clearances Assembly Fitting Adjustable Feet Rear Rollers to Leg Stand Units Fitting Adjustable Feet Rear Rollers to Cabinet and Refrigeration Bases Gas Connection Commissioning O...

Page 4: ...E INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE Warning INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS...

Page 5: ...lot and Flame Failure Protection 3 Base Stand Options B Bench Top CB Cabinet Base LS Leg Stand RB Refrigerated Base RN8900G model only General A heavy duty high efficiency open burners Cooktops for mo...

Page 6: ...J hr 28 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Gas Connection See Gas Connection information overleaf Natural Gas LP Gas Input Rate N H G C each O...

Page 7: ...ly connection point is located at rear of appliance approximately 130mm from right hand side 32mm from rear and 655mm from floor 55mm from floor for bench top B models and is reached from beneath appl...

Page 8: ...6 Dimensions Bench Top Models RN L 8450G B RN L 8900G B...

Page 9: ...7 Dimensions Cabinet Base Models RN L 8450G CB RN L 8900G CB Rating Plate Location for this option R R...

Page 10: ...8 Dimensions Leg Stand Models RN L 8450G LS RN L 8900G LS Rating Plate Location for this option R R...

Page 11: ...9 Dimensions Dimensions for Refrigerated Base Models RN8450G models not available in Refrigerated Base option RN L 8900G RB Rating Plate Location for this option R R...

Page 12: ...are only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protec...

Page 13: ...ach kit Bench Models 1 Check all feet are fitted 2 Adjust four feet to make Cooktop steady and level Fitting of Adjustable Feet Rear Rollers to Leg Stand Units 1 Remove all pot stands trivets and open...

Page 14: ...of base tray to rear cooktop legs and tighten up bolts using a 24mm socket b Fit rear rollers to rear leg supports c Secure rear rollers to rear leg supports using locating screw supplied d Tighten s...

Page 15: ...r and adjust adjustable feet to level appliance Rear Rollers Fitting 1 Raise appliance from floor by approximately 75mm using suitable lifting equipment i e Palletiser Forklift to allow rear adjustabl...

Page 16: ...he gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per Gas Conversion Section in this manual Ensure regulator is converted to correct gas type that ap...

Page 17: ...of Date of Purchase Date of Installation and Serial Number of Appliance recorded and kept with this manual These details can be found on Rating Plate For Cabinet Base and Leg Stand Models Rating Plate...

Page 18: ...n Burners PF Option Description of Controls NOTE The open burner control knobs with Flame Failure Option Only will only have the Off Low Flame and High Flame positions Open Burner F Option Only OFF Po...

Page 19: ...incorporated for each burner by way of a thermo electric system which will shut off gas supply to that burner in the event that burner goes out so that un burnt gas is not expelled a Select burner re...

Page 20: ...aning material has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas electrical suppl...

Page 21: ...ishwasher 2 Burner mounting rails should not be removed Clean in situ with hot soapy water 3 Clean burner venturi with a bottle brush and hot soapy water as required 4 Empty spill tray and wash with w...

Page 22: ...t empty Call service provider Pilot goes out when gas control knob released Open Burner PF options only Releasing knob before thermocouple has heated Pilot flame too small Gas pressure too low Partial...

Page 23: ...nds burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refit the pot sta...

Page 24: ...e adjust regulator if required 5 Screw cap nut back onto regulator Gas Type Identification Label 1 On completion of gas conversion replace gas type identification label located at 2 Rear of appliance...

Page 25: ...l Gas G20 Propane G31 Open Burner Main Burner Injectors 2 30mm 1 40mm Pilot Burner PF Models only 0 30 0 20 Supply Pressure 20 mbar 30 37 mbar Burner Operating Pressure 9 5 mbar 26 mbar Gas Regulator...

Page 26: ...r operating pressure using adjustable gas regulator supplied Natural Gas Town Gas Open Burner Main Burner 2 45mm 4 50mm Pilot Burner PF Models only 0 30 0 60 Supply Pressure 1 13 3 4 kPa 0 75 1 5 kPa...

Page 27: ...n only 229442 Pilot Bracket Assembly PF Option only 229444 Pilot Burner Shield PF Option only 227405 Gas Control F Models 227403 Gas Control PF Models 227967 Knob Open Burner F Models 227384 Knob Open...

Page 28: ...rmation refer to Refrigeration Cabinet Installation and Operation Manual supplied with appliance Gas Type Model Gas Regulators Part No Description Nat Gas LPG Butane RN8400G RN8600G RN8800G 228531 BSP...

Page 29: ......

Reviews: