6 COMPONENTS
(CONT.)
FOR A 24” OR 36” UNIT — To replace a solenoid valve:
A 24” or 36” unit has only ONE side manifold in the LEFT LEG and ONE Front Manifold.
1.
DANGER: Turn off gas supply and remove main power supply to the unit.
2. Remove the Left Side Leg Panel, Knobs and Valve Panel (see sections 6.1, 6.2, and 6.3).
3. Loosen the adapter connecting to the front manifold elbow.
tip
Use double-wrenching (15/16 and 13/16) method to prevent the bottom fitting from
moving while turning the top fitting.
4. Loosen the connector at the inlet box at the back.
5. Remove the screw to release the solenoid bracket.
6. Disconnect wires and remove the solenoid valves and side manifold assembly.
i
Ensure you mark the wires and have a copy of the wiring diagram for reference.
7.
i
Replace the
solenoid
in the
CORRECT
direction
and reassemble.
8.
WARNING: Check for gas leak.
9.
i
To avoid pinching the wires, tuck the wires safely away before sliding back the Leg Panel.
3
3
4
5
Содержание HEEGM48CL
Страница 34: ...Page 34 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS HEEGM24CL 120VAC ...
Страница 35: ...Page 35 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS CONT HEEGM24CL 240VAC ...
Страница 37: ...Page 37 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS CONT HEEGM36CL 240VAC ...
Страница 41: ...Page 41 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS CONT HEEGM60CL 240VAC ...
Страница 43: ......