33
Detector’s test button is pressed.
D#1019 - Panel AC Failure
When AC power fails for more than 10
seconds, Green LED flashes every
second with a beep every 30 seconds.
D#1019 – Panel Low Battery / Panel
Battery Disconnection
When CTC-1052 is under Low Battery
status, Green LED flashes every 2
seconds.
When CTC-1052 is under Battery Not
Connected status, the Green LED
flashes every 2 seconds.
5.3. Scancom Event Code
515555517 - Panel emergency / Pendant
1 emergency / WS emergency / Fall
emergency / WTR / PB emergency
When the Red HELP Panel button is
pressed.
When Pendant 1 is pressed or
triggered.
When Water Sensor is triggered.
When Fall Sensor is pressed or
triggered.
When WTR (non Pendant 1 or Pendant
2) or PB is pressed.
555155517 - Pendant 2 emergency
When Pendant 2 is pressed or
triggered.
515555518 – Pendant 1 Emergency (Low
Battery)
When Pendant 1 is pressed or
triggered under Low Battery status.
555155518 – Pendant 2 Emergency (Low
Battery)
When Pendant 2 is pressed or
triggered under Low Battery status.
551555517 – Mobility/Inactivity
When CTC-1052 makes Mobility Timer
Expired reporting.
If no sudden movement within 10
seconds after fall detection, an inactivity
code will be sent to Central Monitoring
Station.
555556558 - Panel Low battery / Panel
Battery Disconnection
When CTC-1052 is under Low Battery
status, the Green LED flashes every 2
seconds.
When CTC-1052 is under Battery Not
Connected status, the Green LED
flashes every 2 seconds.
555551557 - AC Failure
When the AC power fails for more than
10 seconds, the Green LED flashes
every second with a beep every 30
seconds.
555553557 - AC Failure Restore / Panel
Low Battery restore / Panel Battery
Disconnection restore
When the AC power failure status is
restored. .
When the Panel Low Battery status is
restored.
When the Battery Disconnection status
is restored.
515555559 - Global test / WTR
Supervision Failure
When CTC-1052 reports Global Test to
monitoring Center.
When CTC-1052 is unable to receive
the signal transmitted from the Wrist
Transmitter for a pre-set period by
Command #49.
555555559 - Periodic test report / Help
Arrived
When CTC-1052 reports Periodic test
call to Monitoring Center.
When CTC-1052 makes Help Arrived
reporting.
535555557 - WTR Supervision Failure
Restore / WS Emergency Restore
When the WTR supervision failure
status is restored.
When WS emergency status is
restored.
555555558 - Device Low Battery
When devices are under Low Battery
Status, the Green LED flashes every 2
seconds.
555555557 - Device Low Battery Restore