29
2. Control Panel will retry all report
destinations up to 15 times in total.
3. If more than 1 report destinations are set to
a report method (e.g. Digital), the panel will
consider the report method to be
successful if reporting to one of the
destinations succeeds. Control Panel will
completely stop reporting to this report
method after receiving a successful report.
4. If any report method fails after the total of
15 retries, the Control Panel will pause for
10 minutes before restart reporting. Only
failed report method(s) will be retried
During the 10-minute pause, CTC-1052
returns to normal mode with Red LED on:
Press the
Green Reset Button
to
terminate the reporting.
If new event happens, CTC-1052
starts the reporting immediately.
5. The control panel will not stop reporting
until receiving at least 1 successful report
from each report methods
Examples:
Example 1: If one destination is set, the
panel will report as shown below:
1
>
1
>
1
>
1
>
1
> Wait 10 minutes and
restart reporting
Example 2: If two destinations are set, the
panel will report as shown below:
1
>
2
>
1
>
2
>
1
>
2
>
1
>
2
>
1
>
2
> Wait
10 minutes and restart reporting
Example 3: If six destinations are set, the
panel will report as shown below:
1
>
2
>
3
>
4
>
5
>
6
>
1
>
2
>
3
>
4
>
5
>
6
>
1
>
2
>
3
> Wait 10 minutes and restart
reporting
Example 4: If destinations 1 and 2 utilize
digital report method while destination 3
utilizes speech report method:
1
>
2
>
3
>
1
>
2
>
3
>
1 success
>
3
>
3
>
3
> End of report
Status Report
Status report will report according to the rules
described in Emergency Report, except that
there will only be a maximum of 15 retries
regardless of whether the reports were
successful or not.
4.3 Walk Test (Range Test)
Walk Test, or Range test, is a test to check
whether learned-in devices are within signal
range.
You can conduct Walk Test in CTC-1052 under
3 different modes as listed below.
4.3.1. In Learning Mode
Learning Mode is applicable to all devices.
Step 1.
From Idle Mode, press and hold the
Green Reset Button of the CTC-1052.
When pressed, the CTC-1052 will emit
one beep sound initially, and then will
emit a double beep on the 6
th
second.
Step 2.
Release the Green Reset Button at the
voice prompt “Release the Green
button, Ready to learn sensor.” CTC-
1052 is now in learning mode and the
Red LED will start flashing.
Step 3.
Move the device to your desirable
location in the house, and press the
Learn/Test button
of the device to
observe the range of its operation.
Step 4.
If CTC-1052 responds with
one
long
beep
, then the particular device is
within the operation range.
Step 5.
To exit Learning Mode, press both
RESET
and
HELP
buttons at the same
time. Otherwise, CTC-1052 will exit
Learning mode automatically after 5
minutes of inactivity.
4.3.2. In Walk Test Mode
Walk Test Mode is only applicable to Smoke
Detector (SD), Carbon Monoxide Detector (CO),
Motion Sensor (IR), and Water Sensor (WS).
Step 1.
Upon exiting Learning Mode, CTC-
1052 will automatically enter Walk Test
Mode for the devices mentioned above
(SD, CO, IR, WS).
Step 2.
Move the device to your desirable
location in the house, and press the
TEST button
to observe the range of
its operation.
Step 3.
If CTC-1052 responds with
one
long
beep
, then the particular device is
within the operation range.
Step 4.
CTC-1052 will automatically exit Walk
Test Mode after 3 minutes.
Содержание CTC-1052