22
4.1.4.
CTC-1052 Battery Disconnection
CTC-1052 can detect the absence of
battery in the following cases:
Battery switch OFF
Battery not connected
Battery failure.
When the battery disconnection lasts for
10-15 minutes, CTC-1052 will report to the
Monitoring Center and the GREEN LED
flashes slowly.
After the battery is restored for 10-15min,
CTC-1052 will send
Battery Restore
report
to Monitoring Center and the GREEN LED
returns to steady ON.
4.1.5. Devices Low Battery
When CTC-1052 receives a battery low
signal from a particular device, it will report
to the Monitoring Center and the GREEN
LED will flash rapidly until the fault
condition is cleared.
Press the
Green Reset Button
on CTC-
1052, the LED will turn on.
If any device Low Battery signal is received
again, the LED will light up accordingly.
Press the
Green Reset Button
again, the
LED will turn on.
After the faulty battery is replaced, CTC-
1052 will immediately send Battery Restore
report to the Monitoring Center for that
particular device.
4.1.6. Automatic Check-in Report =
Periodic Test Call
When CTC-1052 is programmed to send a
periodical check-in report, CTC-1052 will
report to the Monitoring Center accordingly.
The Periodic-Check-in Timer will be reset
whenever Programming Mode is entered.
4.1.7. Mobility Timer
In order to check the user’s well being, a
Mobility Timer can be set by using
Command #44.
If Mobility Timer is set as
Enable
, a
counting down period starts from:
Immediately after powering up CTC-
1052
Exit Programming Mode
After the pre-set Timer expires, CTC-1052
will emit a long beep and voice prompt
reminder “Inactivity timer expiring, please
reset.” at every 5 minutes to notify the user
for 30 minutes.
(You can enable or disable
the long beep sound, see Command 78 for
details).
When the Mobility timer is not reset after 30
minutes, CTC-1052 will send a
Mobility
Timer Expired
report to the Monitoring
Center.
After CTC-1052 sends a
Mobility Timer
Expired
Report, but the Mobility timer still
not be reset, when reaching next pre-set
time, the CTC-1052 will emit a beep at
every 5 minutes to notify the user for 30
minutes. Yet, if no reset action after 30
minutes, the panel will send another
Mobility Timer Expired
report to the
Monitoring center and the step will
repeatedly until Mobility timer is reset.
Mobility Timer can be reset by pressing
RESET
button once on CTC-1052 or
whenever a movement is detected by PIR
Detector. CTC-1052 will also play a voice
prompt “Inactivity timer reset.” to inform the
user.
To disable the Mobility Timer function:
Set Command #44 to
00
(Disable), or,
Press and hold the
RESET
button on
CTC-1052 for 16 seconds or longer.
<NOTE>
If no movement is detected during preset
mobility time, CTC-1052 will send a CID
event code 641 with a fixed zone number
071 regardless of the zones the triggered
motion detectors occupy.
Disable the Mobility function in idle
mode:
Step 1:
When the system is in Idle Mode, press
& hold the Reset Button for 16
seconds.
Step 2:
During the 16-sec period, CTC-1052 will
emit one short beep
a double beep
continuous three short beeps
a
long beep
.
Содержание CTC-1052