Gardsman CTC-1052 Скачать руководство пользователя страница 16

13 

Command 43  

Periodic Test Call  

 

CTC-1052 can be programmed to make test 
calls  periodically  from  (00)  (no  test  call)  to 
every (1) - (7) or 30 days:    

Function Selection

Result 

(0) 

OFF 

(1) - (7) 

1 - 7 DAYS

(8) 

30 DAYS 

 

Factory Default is set as (

0

), 

OFF

.  

<NOTE> 

 

Whenever  programming  mode  is 
accessed,  CTC-1052  will  reset  the 
Periodic Test Call timer.

 

 

Periodic Test Call will only function  with 
telephone numbers assigned to 

Digital

 

or 

SMS

 reporting method in 

Command 

20-24.

 

 

 

Command 44 

 

Mobility Timer 

This  function  monitors  user  movement  around 
the  premises  and  sends  an  inactivity  report  to 
the  Monitoring  Center  if  the  user  fails  to  reset 
the inactivity timer. 

 

This  will  disable  or  enable  the  Inactivity 
Timer  with  selectable  count  down  periods.  
Options are: 

 

Function Selection 

Result 

 (00) 

DISABLE 

(01) 

1HR 

(02) 

2HR 

..........

 

.........

 

(36) 

36HR 

 

Factory Default is set as (

00

), 

DISABLE

.  

<NOTE> 

 

The  Mobility  Timer  counting  down  can 
be reset by: 

1.  Pressing  the 

Green  Reset  Button

 

on CTC-1052, or, 

2.  Movement 

detected 

by 

PIR 

Detector 

3.  Only workable by entering 2 digits.  

 

When  Mobility  Timer  expires  and  no 
reset  signal  is  received,  CTC-1052 
starts  to  emit  one  long  beep  every  5 
minutes  to  alert  the  user.  (You  can 
enable or disable long beep sound, see

 

Command  78 

for  details).After  30 

minutes, if reset signal is not received, 
a mobility alarm reporting will be made.  

 

The reporting method for mobility alarm 
is  the  same  as  the  emergency  alarm. 
The  report  will  be  sent  based  on  your 
reporting  methods  without  guard  time 
waiting. 

 

When (

00

) is selected, no code is sent 

to Monitoring Center. 

 

When CTC-1052 is in idle mode, press 
and  hold  the 

Green  Reset  Button

  for 

16 seconds, until you hear a long beep. 
Release  the  button  and  the  Mobility 
function will be disabled. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CTC-1052

Страница 1: ...E1 August 25 2017...

Страница 2: ..._______________ 5 3 1 4 SMS Remote Programming __________________________________________ 6 3 2 Programming Your 1052 ______________________________________________ 6 3 3 SMS Remote Programming_______...

Страница 3: ...n Idle Mode ___________________________________________________________________ 30 4 4 Global Test_________________________________________________________ 30 4 5 Factory Reset________________________...

Страница 4: ...c disable mobility setting 4 RED HELP BUTTON with backlight Back lit disigned for easy access at night Backlight illuminates when off hook Backlight flashes during the waiting period until help arrive...

Страница 5: ...y power to CTC 1052 and at the same time recharge the battery It takes approximately 72 hours to fully charge the battery The battery can be manually disconnected by the battery switch located at the...

Страница 6: ...vices such as mobile phones cordless phone or wireless computer network Wi Fi devices Important When drilling into a wall ensure there are no hidden cables or pipes Mounting the Control Panel The Cont...

Страница 7: ...sed the CTC 1052 will emit one beep sound initially and then will emit a double beep on the 6th second 2 Release the Green Reset Button at the voice prompt Release the Green button Ready to learn sens...

Страница 8: ...eparetely that features a built in keypad and LCD display to help you to program the medical alarm panels effeciently and conveniently It also features Once for All Uploading which allows you program...

Страница 9: ...ia SMS commands Please refer to section 3 3 SMS Remote Programming for usage 3 2 Programming Your 1052 How to enter Commands Please make sure CTC 1052 is in Programming Mode RED LED flashes continuous...

Страница 10: ...ly NOTE When entering the phone number entering means a 3 second pause e g Switchboard system extension etc For example the phone number is 21111111 and extension number is 255 Enter 21111111 255 Up t...

Страница 11: ...mbers 2 GPRS IP NOTE The Tel number selected in Command 7 will not be used for alarm and or status reporting even if it is selected in command 5 and or 6 When multiple Tel numbers are selected CTC 105...

Страница 12: ...eeps via the telephone handset to alert the call recipient the remaining time of 20 10 secs Speech Reporting made under Silent Mode set by Command 35 will automatically be switched to Listen in but ca...

Страница 13: ...F CTC 1052 will return to idle mode when Alarm Reporting is completed Function Selection Result 0 OFF Disable 1 ON Enable Factory Default is set as 0 OFF NOTE If the Green Reset Button is not pressed...

Страница 14: ...efault is as 0 Follow On When this function is programmed as 0 after a successful reporting to the Monitoring Center CTC 1052 will automatically enter the Follow On mode as specified by Command 45 Whe...

Страница 15: ...cannot auto answer the call by ring count If you want to do Remote programming please follow the Remote Programming method described in 3 System Confguration 3 1 Entering Programming Mode 3 1 3 Remote...

Страница 16: ...tion Result 00 DISABLE 01 1HR 02 2HR 36 36HR Factory Default is set as 00 DISABLE NOTE The Mobility Timer counting down can be reset by 1 Pressing the Green Reset Button on CTC 1052 or 2 Movement dete...

Страница 17: ...way Full duplex Communication mode for 1 10 minutes set by Command 46 that gives the user the ability to speak directly with the Monitoring Center Personnel NOTE If either Scancom or Tunstall reporti...

Страница 18: ...61 Check SIM Card PIN Code This option is used to check SIM card PIN Code Function Selection Result 0 OFF Disable 1 ON Enable Factory default is set as 0 OFF NOTE If this function is disabled the syst...

Страница 19: ...ion for configuration Example if you want to raise the speaker volume to level 5 in the Two Way mode please enter 2 5 NOTE The volume value in the Listen In or Talk Only mode is adjusted for the best...

Страница 20: ...r followed by If the number is successfully programmed the telephone handset will emit one short beep If the number is unable to be programmed the Control Panel will emit one long beep Auto Answer Num...

Страница 21: ...Any DTMF Function Selection Result 0 Any DTMF 1 OFF HOOK Command 78 Mobility Time Out Warning When Mobility Time expires and no reset signal is received CTC 1052 will emit a long beep every 5 minutes...

Страница 22: ...ant Transmitter WTR Water Sensor WS Fall Sensor Step 1 Enter 94 on the phone set then a short beep will be heard via the phone set If no command is dialed CTC 1052 will exit Programming mode automatic...

Страница 23: ...and returns to idle mode 3 3 SMS Remote Programming NOTE Prior to procced please be reminded to change the language setting of your mobile phone to English Step 1 Use your handset and go into the SMS...

Страница 24: ...anel can program up to 2 Auto Answer Numbers If a user calls the Control Panel using an auto answer number the Control Panel will pick up the call and instantly open up a two way communication with th...

Страница 25: ...s from Immediately after powering up CTC 1052 Exit Programming Mode After the pre set Timer expires CTC 1052 will emit a long beep and voice prompt reminder Inactivity timer expiring please reset at e...

Страница 26: ...e number Step 3 Once the test message is received you can then check the phone number format shown in the received message EXAMPLE With the phone number 0987654321 the format should either INCLUDE or...

Страница 27: ...as been detected to notify the user and Fall detection has restored cancelling help call voice prompt when fall detection has been cancelled Confirmation Beeps After Guard Time expires CTC 1052 will s...

Страница 28: ...Back 1 or Follow On Call Back 2 after alarm reporting it will then wait 5 minutes for Monitoring Center Personnel to call back after reporting NOTE Call back option is disabled by default If Auto Ans...

Страница 29: ...he Monitoring Center can remotely control CTC 1052 by the DTMF commands below Enter 7 to Speaker Volume Control and then press 6 or 4 to increase or decrease the levels of speaker volume in the Two Wa...

Страница 30: ...red CTC 1052 will end the report retry no more and return to idle mode When help has arrived the Green Reset Button can be pressed twice quickly to send a Help Arrived Mode Canceled report to the Moni...

Страница 31: ...y Control and then press 6 or 4 to increase or decrease levels of microphone sensitivity in the Two Way communication mode NOTE Speech Reporting made under Silent Mode or using a Silent Device will au...

Страница 32: ...ere will only be a maximum of 15 retries regardless of whether the reports were successful or not 4 3 Walk Test Range Test Walk Test or Range test is a test to check whether learned in devices are wit...

Страница 33: ...al Test Step 1 Press the Green Reset Button once Step 2 Within 5 seconds press Pendant button Step 3 CTC 1052 will emit a short beep and report to Monitoring Center 4 5 Factory Reset CTC 1052 will cle...

Страница 34: ...hen Carbon Monoxide Detector CO is triggered When the Test Button of Carbon Monoxide Detector CO is pressed 301 Panel AC Failure When AC power fails for more than 10 sec the Green LED flashes every se...

Страница 35: ...assistance 663 Helped arrived mode canceled When the green reset button is pressed twice in help arrived mode to cancel help arrived mode 5 2 Tunstall Event Code D 1011 Panel AC Restored Help Arrived...

Страница 36: ...ion an inactivity code will be sent to Central Monitoring Station 555556558 Panel Low battery Panel Battery Disconnection When CTC 1052 is under Low Battery status the Green LED flashes every 2 second...

Страница 37: ...his device complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received...

Страница 38: ...ct ID 21 Bi 0 Contact ID 1 Scancom 2 Tunstall 3 Speech 4 SMS CID Tel Number 1 Bi Contact ID 22 Bi 0 Contact ID 1 Scancom 2 Tunstall 3 Speech 4 SMS CID Tel Number 2 Bi Contact ID 23 Bi 0 Contact ID 1 S...

Страница 39: ...ay Speak volume 1 digit 1 5 level Bi Two way mode 3 64 Bi Set Microphone Sensitivity Note Mic sensitivity 1 digit 1 5 level Only can be adjusted in the two way mode Bi Two way Mode 3 66 Bi Guard time...

Страница 40: ...t number 1 ACNT1 PROG 1111 ACNT1 1234 To set change the 4 6 8 digit account number for Telephone number 1 Null to clear account number for Telephone number 1 No account number 12 Account number 2 ACNT...

Страница 41: ...delay time for a compatible sensor except Fall Sensor 00 Instant 01 99 1 99 seconds 00 instant reporting 10 10 seconds 43 Periodic test call TESTC PROG 1111 TESTC 0 To set the periodic test call 0 Off...

Страница 42: ...PLA PROG 1111 REPLA 886 0 To replace the Country Code with 0 886 Country Code No country code IP address TCIP1 PROG 1111 TCIP1 192 168 1 110 To set change the IP address for the Monitoring Station Inp...

Страница 43: ...PRS server confiramtion purpose only They do not change the IP address nor the port number settings 2 GPRS functions can only be programed via SMS messages and the commands MUST be sent in this sequen...

Страница 44: ...41 message sent by the cell phone 3 SMS remote programming command can only be sent in the standby mode 4 The SMS command is successfully set after getting a confirmation message...

Страница 45: ...is connected Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible...

Страница 46: ...me si le brouillage est susceptible d en compromettre le fonctionnement IC Radiation Exposure Statement This equipment complies with IC RSS 102 radiation exposure limit set forth for an uncontrolled...

Отзывы: