5. Extended functions
15
When the
is pressed, the first underscore _ starts to
flash. You can now use the
key to set the first day of
the week (Sunday). Then use the
key to confirm the
day of the week. The next underscore _ now flashes. If
you do not want to confirm a day of the week as set,
immediately press
.
You can run through all seven
days of the week in this way. Once you have confirmed
the last day of the week (Saturday), the first unit of the
switch-in point starts to flash. You can either set this
using
or
. Once the last unit of the switch-out
point has been confirmed, the whole switching unit is
activated.
Go to the
[
CONTROL
MENU
]
sub-menu and then the
p
2
TIMER
CONTROL
menu item. You will now see the
p
2
TIMER
CONTROL OFF
default setting. If you press
the
key, the
OFF
value starts to flash. You can now
use the
key to change the value to
ON
. Then please
press the
key again to confirm the entry. The timer is
now switched on for the second pressure range. Please
refer to section 5.1.2 for how to set the parameters for
the 2nd pressure range.
5.4 [Limit values] sub-menu
In the sub-menu
[
LIMIT VALUES
]
are the factory-
set and changeable parameters. These represent:
a)
DESIGN
PRESS
13.0bar
b)
START
ProTECT
0.8bar
c)
EXT. LIMIT
2500RPM
d)
FINAL
TEMP
WARN
110
°
C
e)
FINAL
TEMP
MAX
120
°
C
f)
MIN
START
TEMP
1
°
C
g)
RUN-ON
TIME
90s
h)
SOFT
STOP
30s
i)
VOL.MAX.
2.8m3/min
j)
VOL.MIN.
1.0m3/min
k)
SOFTWARE: DPro-LRS-1.00
Note
The values shown are examples only. The limit values
in your unit may be different.
a) This is your unit's operating pressure. This is also
stamped on the compressor's name plate.
b) To protect the compressor stage, the compressor
only starts up when the compressor's internal
pressure is less than or equal to the set value. If the
compressor's internal pressure is higher when
starting up, the following appears in the display's
third row:
WARNING
START
AFTER
...
alternating with
...
DE-PRESSURISE
c) If an input is programmed on the function
[
EXT.
RPM LIMIT
]
and its contact is closed, the speed
of the plant will be restricted to the value set here.
d) If the final compression temperature reaches
110 °C,
WARNING HIGH
TEMP
appears in the
display's third row.
e) If the final compression temperature reaches
120 °C, the compressor shuts down.
FAULT
COMP
TEMP
then appears in the third row on the
display
f) If the final compression temperature is below 1 °C,
you cannot start the machine.
g) If the compressor is in automatic mode and there is
no line pressure requirement, the
OFF-LOAD xxs
indication appears and the machine goes into off-
load. After the run-on time, the compressor
automatically shuts down and is ready to start
again.
h) In order to protect the compressor stage, once the
key (shut down system) has been pressed, the
compressor is only switched off 30 seconds later.
If using the timer or the remote start / stop function,
the run-on time is also used.
i) The maximum volume flow that may be adjusted in
relation to the compressor is displayed here.
j) The minimum volume flow that may be adjusted in
relation to the compressor is displayed here
k) You can find the software currently loaded on your
unit here.