4. Maintenance ([MAINTENANCE SCHED.] sub-menu)
10
4
Main te na nce ([ MAINTENANCE SCHED.] su b-me nu )
4.1 Maintenance
The maintenance intervals are preset when the
compressor is supplied. You will find more information
in the unit's overall operating instructions.
It may however be necessary for the maintenance -
intervals to be adjusted individually to your ambient
conditions. For example, the air filter's level of
contamination depends on the compressor's intake
conditions.
The GD Pilot allows the operator to program various
maintenance intervals (see section 4.2).
If there is a maintenance interval at 200h (hours), the
compressor is not automatically shut down. The
MAINTENANCE
ELAPSED
message appears on the
display.
If you want the compressor to automatically shut
down when a maintenance interval is due, you have
to set this function. To do this, please go to the
[MAINTENANCE SCHED.]
sub-menu. Go to the last
SHUTDOWN OFF
menu item. Now press the
key. The
OFF
value now starts to flash. By pressing the
key
you can change the value to
ON
. Finally you need to
confirm using .
The compressor now automatically shuts down when
the –100h maintenance interval is displayed.
Once maintenance has been carried out, the
maintenance interval should be reprogrammed. The
maintenance message can be acknowledged using the
key.
4.2 Programming maintenance intervals
To program a maintenance interval, please go to the
[MAINTENANCE
SCHED.] sub-menu.
Here you can
program the maintenance intervals for:
AIR
FILTER
IN
2000h
OIL
FILTER
IN
2000h
SEPARATOR
IN
4000h
OIL
CHANGE
IN
4000h
Go to the menu item required. Please press the
key.
The value then starts to flash. You can use
or
to
now set the value to an interval of 0….9999. Confirm
your entry with the
key.
If you do not want the maintenance intervals to be
monitored, program the intervals to more than 9999
hours in the various menu items.
----
appears on the
display. The maintenance interval is then blocked.
Note
The values shown are examples only. The values used
in your unit may be different.
4.3 Total/load hours counter
You will find the total/load hours counters in the
[MAINTENANCE
SCHED.]
sub-menu. To do this,
please press the
+
keys at the same time.
You
are then taken to the main menu. Then please press
the
key.
You are now in the
[MAINTENANCE
SCHED.]
sub-menu. You can use the
or
keys to now go to the various menu items.
The total hours counter states the time for which your
unit has been in on-load and off-load.
The load hours counter states the time for which your
unit has been in on-load.
Note
The total and load hours are lost when the GD Pilot is
replaced.