13–8–609 Page 5
Failure to observe these notices could result in damage to equipment.
D
Stop the unit if any repairs or adjustments on or around the compressor are
required.
D
Disconnect the compressor unit from its power source, tag and lockout be-
fore working on the unit – this machine is automatically controlled and may
start at any time.
D
An Excess Flow Valve should be on all compressed air supply hoses ex-
ceeding 1/2 inch inside diameter. (OSHA Regulation, Section 1926.302, or
local regulations)
D
Do not exceed the rated maximum pressure values shown on the nameplate.
D
Do not operate unit if safety devices are not operating properly. Check peri-
odically. Never bypass safety devices.