13–8–606 Page 44
SECTION 9
TROUBLE SHOOTING
SYMPTOM
POSSIBLE CAUSE
REMEDY
Compressor fails to start.
1.
Wrong lead connections.
1.
Change leads.
2.
Blown fuses in control
2.
Replace fuse.
box.
3.
Motor starter overload
3. Reset and investigate
heaters tripped.
cause of overload.
4.
Pressure in reservoir.
4.
Inspect blowdown valve.
5.
Read error message on
5.
Replace switch.
control panel. See Section 4.
Compressor starts but
1.
High discharge temperature.
1.
See “High Discharge
stops after a short time.
Air Temperature,” this
section, page 45.
2.
High discharge
2.
Replace switch.
temperature
switch
malfunction.
3.
Blown fuse in starter/
3.
Replace fuse
control box.
(investigate if fuses
continue to blow).
4.
Motor starter overload
4.
Reset and investigate
heaters trip.
cause of overload.
Compressor does not
1.
Improperly adjusted
1.
Refer to Section 4, page
unload (or load).
control.
21, and adjust control.
2.
Air leak in control
2.
Determine source of
lines.
leak and correct.
3.
Restricted control line.
3.
Clean control lines.
4.
Subtractive pilot or blow–
4.
Repair, clean or replace
down valve malfunction.
valve.
Compressor cycles from
1.
Insufficient receiver capacity.
1.
Increase receiver size.
load to unload excessively.
2.
Restriction in control tubing.
2.
Inspect and clean control
tubing.
3. Subtractive pilot setting
3.
Adjust the valve. See
too high.
Section 4, page 24.
Содержание EDF-KB
Страница 14: ...13 8 606 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 15: ...13 8 606 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 34: ...13 8 606 Page 26 FIGURE 4 10 WIRING DIAGRAM FULL VOLTAGE DUAL CONTROL 208EDF546 Ref Drawing...
Страница 36: ...13 8 606 Page 28 FIGURE 5 1 FLOW DIAGRAM 204EDF797 Ref Drawing...
Страница 58: ......