13–8–606 Page 25
Load setpoint cannot be set within 8 psi (.6 Bar) of the unload
setpoint.
Minimum operating pressure is 60 to 65 PSIG (4.1 to 4.5 Bars).
NAMEPLATE CONTROL SYSTEM PRESSURE
FULL LOAD
OPERATING PRESSURE
LOAD
UNLOAD
100 PSI (6.9 Bars)
100 PSI (6.9 Bars)
108 PSI (7.5 Bars)
125 PSI (8.6 Bars)
125 PSI (8.6 Bars)
133 PSI (9.2 Bars)
FIGURE 4–8 – MAXIMUM SETPOINTS FOR AUTO SENTRY “S” CONTROLLER, PSIG
FIGURE 4–9 – AUTO SENTRY “S” SOLID STATE CONTROL TOUCH PAD
Содержание EDF-KB
Страница 14: ...13 8 606 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 15: ...13 8 606 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 34: ...13 8 606 Page 26 FIGURE 4 10 WIRING DIAGRAM FULL VOLTAGE DUAL CONTROL 208EDF546 Ref Drawing...
Страница 36: ...13 8 606 Page 28 FIGURE 5 1 FLOW DIAGRAM 204EDF797 Ref Drawing...