Installation
21
1)
Navigate to the root folder of the device containing the Gamry Software (DVD or Flash Drive) or to a
Windows
®
folder containing the Gamry Software.
2)
Run the program called
“AUTORUN.EXE”
found in this folder.
If you do not know how to navigate to the Gamry Installation device, consult your local computer expert or
network administrator, or email
.
“AUTORUN.EXE”
runs a set-up program. In most cases, you can choose the default choices or the most
obvious choices on all screens shown during the set-up process.
Reboot Your Computer after Software Installation
Reboot your computer when the Gamry Setup program is done. The Setup program normally offers you the
opportunity to do so. USB device drivers are usually loaded when Windows
®
boots up. Following Setup, you
may not be able to use your Interface 5000 until the drivers are loaded.
Power Cord and Power Connection
The Interface 5000 does not plug directly into the AC mains supply. Instead, the mains are connected to an
external power supply, which supplies a regulated 48 V DC output. This regulated DC is then connected to the
DC power input jack on the rear of the Interface 5000.
The external power supply provided with the Interface 5000 is rated for operation from 100 to 240 V AC, at
frequencies from 47 to 63 Hz. It should therefore be useable worldwide.
The Interface 5000 external supply is normally supplied with a line cord suitable for use in the United States. In
other countries, you may have to replace the line cord with one suitable for your type of mains (electrical
outlet). You must always use a line cord with a CEE 22 Standard V (IEC 320 C13) female connector on the end
of the cable leading to the unit. This is the same connector used on the US standard line cord supplied with
your Interface 5000.
The DC output cord from the external power supply plugs into the
Power In
jack on the rear panel of the
Interface 5000 (see Figure 3-2).
The output cable from the external power supply ends in a 3-pin miniature power DIN male
connector. This DIN connector cannot be plugged into either of the other DIN connectors on the Interface
5000. Improper connection is therefore unlikely.
Device driver installation may not occur until a while after the Windows Desktop appears. On
a slow computer, or a busy computer with lots of active applications, the delay before driver installation can
be a minute or more.
Содержание Interface 5000
Страница 2: ...2 ...
Страница 18: ...Introduction 18 ...
Страница 30: ...Installation 30 ...
Страница 36: ...Calibration 36 ...
Страница 64: ...Appendix A Interface 5000 Specifications 64 ...
Страница 72: ...Appendix D Power LED Blink Codes and Error Messages 72 ...
Страница 74: ...Appendix E CE Certificate Declaration of Conformity 74 Low Voltage Certificate of Conformance ...
Страница 75: ...Appendix E CE Certificate Declaration of Conformity 75 RFI Certificate of Conformance ...
Страница 76: ...Appendix E CE Certificate Declaration of Conformity 76 ...
Страница 80: ...Appendix F Heat in Interface 5000 Multichannel Systems Interface Power Hub Systems 80 ...
Страница 85: ......
Страница 86: ...734 Louis Drive Warminster PA 18974 Tel 215 682 9330 Fax 215 682 9331 www gamry com info gamry com ...