All copying, even partial, of this manual is strictly forbidden

RG66007967 - Rev 02

The operating rules in this manual are solely applicable for the following Models:

HiWarm

The instructions manual must be read and used as follows:
-  every unit operator and maintenance technician must carefully read the entire manual and comply with that stipulated 

therein;

-  the employer is obliged to ensure that the operator satisfies the aptitude requisites for unit operation and has carefully 

read the manual;

-  read the instructions manual carefully and consider it an integral part of the unit;
-  the instructions manual must be readily available to the operating personnel and maintenance technicians;
-  keep the manual throughout the life of the unit;
-  make sure that any update is included in the text;
-  pass on the manual to any other use or subsequent owner of the unit;
-  use the manual in such a way so as not to damage any part of the content;
-  for not reason whatsoever are parts of the manual to be removed, torn or rewritten;
-  keep the manual away from humidity and heat;
-  if the manual is lost or partially damaged and therefore the contents can no longer be read entirely, it is advisable to 

request a new manual from the manufacturer by communicating the code found on the cover or the serial number of the 
unit.

Pay utmost attention to the following symbols and their meaning. Their purpose is to highlight specific information such as:

The operating rules described in this manual are an integral part of the unit supply.
These rules are also intended for the previously trained operator specifically to operate this type of unit and contain all the 
necessary and important information for operating safety and optimal, proper use of the unit.
Hurried and incomplete training leads to improvisation, which is the cause of many accidents.
The following recommendations must be read carefully before starting work and strictly complied with:
-  the operator must always have the instructions manual at his disposal;
-  plan each operation carefully;
-  before starting work, make sure the safety devices function correctly and you have no doubts on how they work; otherwise, 

do not start-up the unit;

-  strictly comply with the precautions regarding specific risks referred to in this manual;
-  preventive and thorough maintenance guarantees constant enhanced unit operating safety. Never delay repairs and 

always have them carried out solely by qualified personnel; only original spare parts are to be used.

1 - GENERAL DESCRIPTION

1.1

PRECAUTIONS FOR USE

1.2

PREMISE

WARNING

With reference to additional information or tips for the unit to be used correctly.

ATTENTION

With reference to dangerous situations that could arise while using the unit, in order to 
prevent damaging objects and the unit itself.

With reference to dangerous situations that could arise while using the unit, in order 
guarantee personal safety.

DANGER

Содержание HiWarm Series

Страница 1: ...R410A eco 12 kW 22 kW 33 kW MULTIFUNCTION UNIT AIR WATER HEAT PUMP INSTALLATION USE AND MAINTENANCE MANUAL GB...

Страница 2: ......

Страница 3: ...or optimal use of our product for maximum comfort Please carefully read the recommendations provided in the following pages and place the manual at the disposal of the unit managers and maintenance te...

Страница 4: ...HIWARM 4 All copying even partial of this manual is strictly forbidden RG66007967 Rev 02...

Страница 5: ...m found in the unit documentation by fax at least one week in advance Should this form not be found please contact GALLETTI Tel 39 051 8908111 Fax 39 051 8908122 e mail assistenza galletti it 4 OUR AP...

Страница 6: ...2 3 Operational safety 14 2 2 4 Residual risk areas 14 2 3 LOCATION OF THE SAFETY LABELS 15 2 3 1 Description of the safety labels 15 2 4 GENERAL SAFETY RULES 17 2 4 1 Attention and maintenance 17 2 4...

Страница 7: ...D MANAGEMENT FUNCTION 41 6 3 USER INTERFACE 42 6 3 1 Description of the keypad 42 6 3 2 Main screen 43 6 3 3 Selecting the control mode 43 6 3 4 Selecting the set point 46 6 3 5 Alarms 47 6 3 6 Operat...

Страница 8: ...bols and their meaning Their purpose is to highlight specific information such as The operating rules described in this manual are an integral part of the unit supply These rules are also intended for...

Страница 9: ...e take all the precautions necessary The pressurised fluids in the cooling circuit and the presence of electrical components can cause hazardous situations during installation and maintenance operatio...

Страница 10: ...t kg 50 Alimentazione Power supply 230 1 50Hz Potenza assorbita Massima Maximum power input kW 0 4 Corrente massima Full load ampere FLA A 1 66 Corrente di spunto Starting Current LRA A 0 0 10 All cop...

Страница 11: ...erstood the user instructions well together with the meaning of any symbols on the unit Potential accidents can be prevented by following these technical instructions with reference to the Machinery D...

Страница 12: ...he Standards in force Apply a WORKS IN PROGRESS sign on all sides of the unit Carefully check the unit according to the list of operations specified in this manual The unit must only be used by qualif...

Страница 13: ...ith the unit off and the power supply disconnected Once the unit is cleaned the operator must make sure there are no worn or damaged parts or others that are not fastened securely otherwise a maintena...

Страница 14: ...arts are used has a component that is either modified or replaced without written authorisation from the MANUFACTURER especially when the efficiency of the safety systems is intentionally reduced or e...

Страница 15: ...e functions of the unit and the consequent risks b Read the use and maintenance manual carefully before operating the unit Power supply label a Do not use water to extinguish fire b Do not smoke and o...

Страница 16: ...l copying even partial of this manual is strictly forbidden RG66007967 Rev 02 a Electric voltage hazard b Risk of shearing in the finned coil area c Risk of burns Liquid refrigerant Hazard moving mech...

Страница 17: ...check that the safety devices are in perfect working condition Make sure that no unqualified or unauthorised persons enter the unit area Verify that the fire extinguisher is in place Periodically veri...

Страница 18: ...solvents must be used even if weak as they damage the paint and increase the formation of rust If a jet of water penetrates the electrical equipment the contacts oxidise and the unit can malfunction T...

Страница 19: ...oned at a height with simple brackets Outdoor unit for indoor use ductable compact with backward curved blade fans activated by an EC synchronous permanent magnets motor designed for attics Expansion...

Страница 20: ...or unit side panelling in galvanised sheet metal painted with polyester epoxy powders and polymerised in the oven at 180 C and a front cover that incorporates the Display on two basic levels LCD and a...

Страница 21: ...manual is strictly forbidden RG66007967 Rev 02 3 2 MAIN COMPONENTS OF THE INDOOR UNIT PLATE HEAT EXCHANGERS DISPLAY INVERTER SOLENOID VALVES LIQUID SEPARATOR COMPRESSOR CYCLE INVERSION VALVE LIQUID RE...

Страница 22: ...well as the need to minimise the amount of oil entrained into the transients and is a parameter that cannot be modified INTERNALTEMPERATURE C M O D E L W I T H I N V E R T E R STANDARDMODEL TIME Scro...

Страница 23: ...at of R407C units of the same size 20 operating energy supplied by renewable photovoltaic panels 100 useable kW 80 energy absorbed from the environment renewable clean energy TEWI Total Equivalent War...

Страница 24: ...same IN OUT configuration and the user does not notice any change N B the above mentioned selection always considers a heat exchange in countercurrent mode Countercurrent Cocurrent Electronic expansio...

Страница 25: ...n consists of an electrical current being applied to a coil that creates a magnetic field This is transformed into mechanical energy which opens or closes the valve The principle of operation is very...

Страница 26: ...ency TheBLDCdoesnotrequireinductioninthestatorwindings there already is a permanent magnet in the rotor There are no relative losses The BLDC has no rotor currents due to the stator induction of the a...

Страница 27: ...ber of 25 x 21 65 mm expanded pipes 8 mm diameter in an automatic and controlled process in 0 10 mm thick aluminium fins Expansion is a fey factor and important process as it determines the pipe fin c...

Страница 28: ...ng and cooling requirements throughout the year with no fossil fuels Three models can be chosen from classified according to the maximum cooling capacity they can produce Priority production of domest...

Страница 29: ...r Domestic hot water Water mains Water mains Storage tank Storage tank Storage tank Storage tank Fan coil Fan coil Flooring Flooring REMOTE UNIT REMOTE UNIT DOMESTIC HOT WATER DOMESTIC HOT WATER HOME...

Страница 30: ...the pipes to use to connect the indoor and the outdoor units according to the different sizes of the HiWarm and the length of the line Model 012 022 033 Refrigerant R410A Pipe length m 0 5 6 10 11 15...

Страница 31: ...icting the availability of oxygen Once evacuated the area must be ventilated with fans or blowers in order to circulate the air at floor level FLAMMABILITY according to the 34 ASHRAE Standard R 410A i...

Страница 32: ...l of this manual is strictly forbidden RG66007967 Rev 02 HiWarm 12 operating limits for the following produced water and outdoor air temperature HiWarm 22 operating limits for the following produced w...

Страница 33: ...ure differential of 8 C lower flow rates could cause excessively low evaporation temperatures which could trigger the safety devices and stop the unit or cause incorrect distribution and risk of heat...

Страница 34: ...ign of damage Commissioning report wiring diagram warranty certificate and list of service centres check the integrity of the documents accompanying the unit and of this manual While the unit is being...

Страница 35: ...ol on the water side allows the correct functionality of the expansion tank to be verified and any water leaks in the system to be detected in advance sumps on inlet and outlet piping for temperature...

Страница 36: ...useful head of the hydraulic pumps in cooling conditions water 12 7 C and air 35 C Inverter driven pumps can run within the limited range over the characteristic range of the pump 012 Absorbed power...

Страница 37: ...37 All copying even partial of this manual is strictly forbidden RG66007967 Rev 02 022 Absorbed power kW 0 3 Absorbed current A 1 3 033 Absorbed power kW 0 3 Absorbed current A 1 3...

Страница 38: ...it Lastly it is possible to find the minimum recommended protection For the correct sizing of the cable it is necessary to take into account standard reference IEC EN60204 1 1 The selected upstream pr...

Страница 39: ...the internal and external unit for a maximum distance of 30m When connecting units with EC fans the power and signal cables must be separate and sized as indicated in the table The 0 10V signal cable...

Страница 40: ...can be set downloading all the data records from a web browser or via FTP editing the main parameters in case of an alarm sending an e mail to 5 different recipients GWeb also allows for monitoring to...

Страница 41: ...ds and the branch point of the power supply for the power factor correction panel the installed CT must measure all the absorbed currents of the system inductive motors or similar as well as capacitiv...

Страница 42: ...ress the PRG key to enter the main menu ESC Press the ESC key to move up one level in the menu UP Press the UP key to go to the next screen or increase the value of a parameter ENTER PresstheENTERkeyt...

Страница 43: ...er the main menu use the UP and DOWN keys to scroll the menu to select USER press ENTER and enter the password default 100 using the UP and DOWN keys press ENTER to confirm the password and access the...

Страница 44: ...nication board is installed pCOWeb or RS485 that acts as an interface between the main unit control and the supervision system The type of protocol and main communication configuration parameters can...

Страница 45: ...hours Band 3 F3 the unit is always on Band 4 F4 the unit is always off Weekly program configuration Once the On Off bands are set they must be used to define the logic of the different days of the wee...

Страница 46: ...screen Time band set point solely for the utility A time band for each day of the week can be set from the SET POINT menu to control the variation of the set point during the intervals of the day when...

Страница 47: ...lights up Press the ALARM key once to access the list of active alarms then use the UP and DOWN keys to scroll the list Each alarm is identified by a code and a brief description the complete list is...

Страница 48: ...ALARM 013 LOW PRESSURE ALARM 015 PRESSURE SWITCH OR COMPRESSOR CIRCUIT BREAKER HIGH PRESSURE ALARM 017 LOW PRESSURE PROBE ALARM 019 HIGH PRESSURE PROBE ALARM 023 FAN CIRCUIT BREAKER ALARM 025 PUMP 1 E...

Страница 49: ...VE BOARD ALARM With Frecon APY inverter heat sink over temperature overcurrent during acceleration overcurrent overcurrent during deceleration DC Bus undervoltage DC Bus overvoltage faulty PFC convert...

Страница 50: ...unit Faulty high pressure Insufficient air flow rate to the condenser Check that all fans turn correctly Check the condenser air inlet T and prevent any recirculation Check that the maximum RMS voltag...

Страница 51: ...the filter must not exceed 2 C saturation temperature Should it happen replace the filters Low condensation T Make sure the condensation control works properly if present Low refrigerant charge Check...

Страница 52: ...rs that are too high This leads to regular and continuous system operation and therefore better thermal performance The water heated by the unit is stored inside the tank and the energy stored this wa...

Страница 53: ...4 41 6 34 3 46 6 80 3 47 UTILITYWater Flow Rate kg h 714 2696 1458 4834 1472 7565 UTILITYWater Pressure Drops kPa 3 0 37 0 4 0 49 0 11 1 44 0 DISSIPATIONWater Flow Rate m3 h 3500 7000 5250 10500 7000...

Страница 54: ...0 30 0 45 0 45 0 60 0 60 Fan Absorbed Current A 1 40 1 40 0 80 0 80 1 10 1 10 COP 3 48 4 03 3 69 3 65 3 91 3 71 UTILITYWater Flow Rate kg h 527 2093 1050 4034 1687 6147 UTILITYWater Pressure Drops kPa...

Страница 55: ...atetheworkcarriedoutinthewastecollection disposalandrecyclingfacilitiesandminimisetheenvironmental impact of such processes The law EC 2037 00 that regulates the use of stratospheric ozone depleting s...

Страница 56: ...not smoke SPECIAL PROTECTION SYSTEMS FOR THE FIRST AIDERS Wear breathing apparatus and protective clothing MEASURES IN CASE OF ACCIDENTAL DISPERSION PERSONAL PRECAUTIONS Avoid contact with your skin e...

Страница 57: ...ic components the product can cause the following due to vapour accumulation and or inhalation of large quantities Loss of consciousness and cardiac disorders aggravated by stress and lack of oxygen L...

Страница 58: ...ackaging group Classification code 2A Labels 2 2 ADN ADNR Substance identification number 3163 Hazard identification number 20 Class 2 Number and letter 2nd A Labels 2 IMDG ONU No IMDG 3163 Class 2 2...

Страница 59: ...59 All copying even partial of this manual is strictly forbidden RG66007967 Rev 02 NOTES...

Страница 60: ...www galletti it 40010 Bentivoglio BO Via Romagnoli 12 a Tel 051 8908111 Fax 051 8908122 Company UNI EN ISO 9001 and OHSAS 18001 certified...

Отзывы: