DMC-1500
Chapter 3 Connecting Hardware
•
29
1 mA < V supply/(R + 2.2K
Ω
) < 15 mA
f
(For Voltages > +28V)
Isolated
Supply
FLS
2.2K
LSCOM
Figure 3-2. Connecting a single Limit or Home Switch to an Isolated Supply
NOTE:
As stated in Chapter 2, the wiring is simplified when using the ICM-1100 or AMP-11x0
interface board. This board accepts the signals from the ribbon cables of the DMC-1500 and provides
phoenix-type screw terminals. A picture of the ICM-1100 can be seen on pg. 2-14. The user must
wire the system directly off the ribbon cable if the ICM-1100 or equivalent breakout board is not
available.
Bypassing the Opto-Isolation:
If no isolation is needed, the internal 5 Volt supply may be used to power the switches, as shown in
Figure 3-3. This can be done by connecting a jumper between the pins LSCOM or INCOM and 5V,
labeled J9. These jumpers can be added on either the ICM-1100 or the DMC-1500. This can also be
done by connecting wires between the 5V supply and common signals using the screw terminals on
the ICM-1100 or AMP-11x0.
To close the circuit, wire the desired input to any ground (GND) terminal.
Содержание DMC-1510
Страница 6: ......
Страница 18: ...6 Chapter 1 Overview DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 88: ...76 Chapter 6 Programming Motion DMC 1500 Figure 6 7 Motion intervals in the Home sequence...
Страница 90: ...78 Chapter 6 Programming Motion DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 137: ...DMC 1500 Chapter 7 Application Programming 125 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 157: ...DMC 1500 Chapter 10 Theory of Operation 145 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 160: ...148 Appendices DMC 1500 Card Level Layout...
Страница 178: ...166 Appendices DMC 1500 ICM 1100 Drawing 1 3 4 0 0 4 4 0 2 4 0 7 0 0 4 5 3 7 0 5 7 0 2 8 5 1 0 0 1 0 1 0 7 0 1 0 0...
Страница 180: ...168 Appendices DMC 1500...
Страница 198: ...186 Appendices DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...