DMC-1500
Chapter 7 Application Programming
•
121
Further assume that the Z must move 2" at a linear speed of 2" per second. The required motion is
performed by the following instructions:
Instruction Interpretation
#A Label
VM XY
Circular interpolation for XY
VP 160000,160000
Positions
VE
End Vector Motion
VS 200000
Vector Speed
VA 1544000
Vector Acceleration
BGS Start
Motion
AMS
When motion is complete
PR,,-80000
Move Z down
SP,,80000 Z
speed
BGZ
Start Z motion
AMZ
Wait for completion of Z motion
CR 80000,270,-360
Circle
VE
VS 40000
Feedrate
BGS
Start circular move
AMS
Wait for completion
PR,,80000
Move Z up
BGZ
Start Z move
AMZ
Wait for Z completion
PR -21600
Move X
SP 20000
Speed X
BGX Start
X
AMX
Wait for X completion
PR,,-80000 Lower
Z
BGZ
AMZ
CR 80000,270,-360
Z second circle move
VE
VS 40000
BGS
AMS
PR,,80000 Raise
Z
BGZ
AMZ
VP -37600,-16000
Return XY to start
VE
VS 200000
BGS
AMS
EN
Содержание DMC-1510
Страница 6: ......
Страница 18: ...6 Chapter 1 Overview DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 88: ...76 Chapter 6 Programming Motion DMC 1500 Figure 6 7 Motion intervals in the Home sequence...
Страница 90: ...78 Chapter 6 Programming Motion DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 137: ...DMC 1500 Chapter 7 Application Programming 125 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 157: ...DMC 1500 Chapter 10 Theory of Operation 145 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 160: ...148 Appendices DMC 1500 Card Level Layout...
Страница 178: ...166 Appendices DMC 1500 ICM 1100 Drawing 1 3 4 0 0 4 4 0 2 4 0 7 0 0 4 5 3 7 0 5 7 0 2 8 5 1 0 0 1 0 1 0 7 0 1 0 0...
Страница 180: ...168 Appendices DMC 1500...
Страница 198: ...186 Appendices DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...