Debugging Example:
The following program has an error. It attempts to specify a relative movement while the X-axis is
already in motion. When the program is executed, the controller stops at line 003. The user can then
query the controller using the command, TC1. The controller responds with the corresponding
explanation:
Instruction Interpretation
:ED Edit
Mode
000 #A
Program Label
001 PR1000
Position Relative 1000
002 BGX
Begin
003 PR5000
Position Relative 5000
004 EN
End
<cntrl> Q
Quit Edit Mode
:XQ #A
Execute #A
?003 PR5000
Error on Line 3
:TC1
Tell Error Code
?7 Command not valid
while running.
Command not valid while running
:ED 3
Edit Line 3
003 AMX;PR5000;BGX
Add After Motion Done
<cntrl> Q
Quit Edit Mode
:XQ #A
Execute #A
Program Flow Commands
The DMC-1500 provides instructions to control program flow. The DMC-1500 program sequencer
normally executes program instructions sequentially. The program flow can be altered with the use of
event triggers, trippoints, and conditional jump statements.
Event Triggers & Trippoints
To function independently from the host computer, the DMC-1500 can be programmed to make
decisions based on the occurrence of an event. Such events include waiting for motion to be complete,
waiting for a specified amount of time to elapse, or waiting for an input to change logic levels.
The DMC-1500 provides several event triggers that cause the program sequencer to halt until the
specified event occurs. Normally, a program is automatically executed sequentially one line at a time.
When an event trigger instruction is decoded, however, the actual program sequence is halted. The
program sequence does not continue until the event trigger is "tripped". For example, the motion
complete trigger can be used to separate two move sequences in a program. The commands for the
second move sequence will not be executed until the motion is complete on the first motion sequence.
In this way, the DMC-1500 can make decisions based on its own status or external events without
intervention from a host computer.
Содержание DMC-1510
Страница 6: ......
Страница 18: ...6 Chapter 1 Overview DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 88: ...76 Chapter 6 Programming Motion DMC 1500 Figure 6 7 Motion intervals in the Home sequence...
Страница 90: ...78 Chapter 6 Programming Motion DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 137: ...DMC 1500 Chapter 7 Application Programming 125 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 157: ...DMC 1500 Chapter 10 Theory of Operation 145 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 160: ...148 Appendices DMC 1500 Card Level Layout...
Страница 178: ...166 Appendices DMC 1500 ICM 1100 Drawing 1 3 4 0 0 4 4 0 2 4 0 7 0 0 4 5 3 7 0 5 7 0 2 8 5 1 0 0 1 0 1 0 7 0 1 0 0...
Страница 180: ...168 Appendices DMC 1500...
Страница 198: ...186 Appendices DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...