58
•
Chapter 6 Programming Motion
DMC-1500
EM
6000,1500
Step 3.
Specify the master interval and starting point.
Next we need to construct the ECAM table. The table is specified at uniform intervals of master
positions. Up to 256 intervals are allowed. The size of the master interval and the starting point are
specified by the instruction:
EP
m,n
where m is the interval width in counts, and n is the starting point.
For the given example, we can specify the table by specifying the position at the master points of 0,
2000, 4000 and 6000. We can specify that by
EP
2000,0
Step 4.
Specify the slave positions.
Next, we specify the slave positions with the instruction
ET[n]=x,y,z,w
where n indicates the order of the point.
The value, n, starts at zero and may go up to 256. The parameters x,y,z,w indicate the corresponding
slave position. For this example, the table may be specified by
ET[0]=,0
ET[1]=,3000
ET[2]=,2250
ET[3]=,1500
This specifies the ECAM table.
Step 5.
Enable the ECAM
To enable the ECAM mode, use the command
EB
n
Содержание DMC-1510
Страница 6: ......
Страница 18: ...6 Chapter 1 Overview DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 88: ...76 Chapter 6 Programming Motion DMC 1500 Figure 6 7 Motion intervals in the Home sequence...
Страница 90: ...78 Chapter 6 Programming Motion DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 137: ...DMC 1500 Chapter 7 Application Programming 125 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 157: ...DMC 1500 Chapter 10 Theory of Operation 145 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 160: ...148 Appendices DMC 1500 Card Level Layout...
Страница 178: ...166 Appendices DMC 1500 ICM 1100 Drawing 1 3 4 0 0 4 4 0 2 4 0 7 0 0 4 5 3 7 0 5 7 0 2 8 5 1 0 0 1 0 1 0 7 0 1 0 0...
Страница 180: ...168 Appendices DMC 1500...
Страница 198: ...186 Appendices DMC 1500 THIS PAGE LEFT BLANK INTENTIONALLY...