GPS 2300 PFC BI-PULSE
20
CYCLE PARAMETERS FOR Bi-PULSED MIG WELDING MODE IN CONTINUOUS CYCLE
Parameter
PARAMETER DESCRIPTION
CONFIGURABLE
VALUE
FACTORY VALUE
D
Drop detachment force correction.
-10 ÷ 10
(20 positions)
0
CBP
Arc length correction in upper working point of dual pulsed
arc.
-30%÷ 30%
U
2
upper
0 %
MOD
Pulse mode (2S, 4S and 4S special)
2S ; 4S ; 4SS
2S
TPR
Gas pre-flow time.
0÷3.0 s
0.3
(s)
TC
Striking ascent ramp time
0 ÷ 500 ms
100 ms
IS
Start current
5÷200
130%
TS
IS time
0.0÷5.0 s
0.1
s
CCE
U2 correction in IS
-30 +30%
0
DWS1
Start current ramp (only in 2S-S and 4S-S mode)
0÷10.0 s
0.6
(s)
CBP
Bi-Pulsed arc correction
-30 +30%
0%
FBP
Dual pulsed-arc frequency
0.5÷5.0 Hz
3.3 Hz
DBP
Speed
differential for obtaining both working points of the
dual pulsed arc.
10 + 80 %
35 %
DCL
Time of dual pulsed-arc high speed.
20÷ 80 % (1/FBP)
50 %
DWS2
END current ramp (only in 2S-S and 4S-S mode)
0÷10.0 s
0.6
(s)
IE
End crater current (only in 2S-S and 4S-S mode)
10÷200% vh
50% vh
TE
IE time (only in 2S-S
TPS
Gas post-flow time.
0.0÷5.0 s
0.5
(s)
FDC
Approach speed.
10 ÷100% Vh
33
(% vh)
TBB
After-burning time correction.
-20 ÷ 20 (ms)
0
(150 – 4*Vh)
DIM
Dimensional system (Ø/vh).
MM; IN
MM
REF
Cooling mode
AUT/ON/OFF
OFF
Explanatory notes:
Tacer: The time that it is in approach process (I
2
=0) will be limited to 5 s.
Tci: If the arc is manually interrupted (l2=0) during the welding process, the cycle will be suspended if the welding position (l2>0) is not recuperated
in 4 seconds.
4SS pulse mode and Bi-Pulsed mode signalling
The 4S "Special" mode will be indicated with the symbol
situated further to the right, and which will be flashing.
The Bi-Pulse mode (FBP
OFF) will be showed with the indication “PULSE “ flashing.
Содержание GPS 2300 PFC BI-PULSE
Страница 36: ...GPS 2300 PFC BI PULSE 36 NOTES...
Страница 40: ...REPUESTOS GPS 2300 PFC REF 532 00 100 15 1 19 HR 53200100 V0 1 2 PARTS LIST GPS 2300 PFC 1Ph 230V 50 60 Hz...
Страница 42: ......