GPS 2300 PFC BI-PULSE
16
3.4.4.3. CYCLE PARAMETERS. MIG PROCESS (CONTINUOUS)
MIG PROCESS OPERATING CYCLES
2S/4S MOD (2/4 STROKES)
Torch
U
2
2T
I2>0
Vh
TPR
GAS
TBB
TPS
tacer
1T
3T
4T
FDC
1T
2T
2S-S/4S-S MOD (2/4 STROKES-SPECIAL)
CYCLE PARAMETERS FOR STANDARD MIG WELDING MODE IN CONTINUOUS CYCLE
Parameter
PARAMETER DESCRIPTION
CONFIGURABLE
VALUE
FACTORY VALUE
L
Electronic inductance level. (dynamic)
-10 ÷ 10
(20 adjustment
points)
0
MOD
Pulse mode (2S, 2S-S, 4S and 4S-S)
2S; 2S-S; 4S; 4S-S
2S
TPR
Gas pre-flow time.
0÷3.0 s
0.3
(s)
TC
Striking ascent ramp time
0-500 ms
130
TPS
Gas post-flow time.
0.0÷5.0 s
0.5
(s)
IS
Start current (2S-S and 4S-S)
5÷200
130
S-S
IS time
0.0÷5.0 s
0.1
CCE
U2 correction in IS
-30 +30%
0
DWS1
Start current ramp (only in 2S-S and 4S-S mode)
0÷10.0 s
0.6
(s)
DWS2
END current ramp (only in 2S-S and 4S-S mode)
0÷10.0 s
0.6
(s)
IE
Final current
10 -200%
50%
FDC
Approach speed.
10 ÷100% Vh
33
(% vh)
TPS
Gas post-flow time.
0.0÷5.0 s
0.5
(s)
FDC
Approach speed.
-80 ÷100% Vh
33
(% vh)
TBB
After-burning time correction.
-20 ÷ 20 (ms)
0.00
(150 – 4*Vh)
DIM
Dimensional system (Ø/vh).
MM ; IN
MM
REF
Cooling mode
AUT/ON/OFF
OFF
Содержание GPS 2300 PFC BI-PULSE
Страница 36: ...GPS 2300 PFC BI PULSE 36 NOTES...
Страница 40: ...REPUESTOS GPS 2300 PFC REF 532 00 100 15 1 19 HR 53200100 V0 1 2 PARTS LIST GPS 2300 PFC 1Ph 230V 50 60 Hz...
Страница 42: ......