3.5. TIG WELDING. INSTALLATION, START-UP AND OPERATING CONTROLS.
Depending on whether the installation is cooled or not, we must set the equipment during the first start-up.
AUTOMATIC COOLING:
Working mode with cooled torch.
The cooling only works in welding mode and will switch off automatically 2 minutes after carrying out the welding
process.
Automatic disconnection time (120s – Troff2: Not adjustable value).
COOLING “ON”:
Working mode with cooled torch.
The cooling works permanently after the first welding process starts.
COOLING “OFF”:
It enables to work with torches without water cooling.
The cooling is deactivated, the protection against lack of water pressure is disabled.
Setting parameters adjustment system for (automatic) cooled installation :
P1: SELECT THE
PROCESS
P1: ENTER/EXIT TO
PARAMETERS
SETTING MODE
E1: SELECT CYCLE
PARAMETER
E2: ADJUST VALUE
P1: SAVE
PARAMETERS
SETTING
PARAMETERS
D2:
D3:
SAVED
PARAMETERS
PULSE