REG24: Special Mode Settings
[default value: C0H]
Bit 7 : reserved
•
The FDL01TU does not use this register. Keep the default value as it is.
Bit 6: Transmission trigger (Headerless stream mode)
0
Need trigger even if data number exceeds 255 bytes(default value)
1
Transmit without trigger when the data number exceeds 255 bytes
Table 5–26: Transmission trigger setting
•
Sets the trigger mode of the Headerles stream mode.
Bit 5 – 2: reserved
•
The FDL01TU does not use this register. Keep the default value as it is.
Bits 1 – 0: Reception protocol
Bit 1
Bit 0
Setting
0
0
Receive with the setting of REG18 bit7 to bit6(default value)
0
1
Receive with the packet transmission mode
1
0
Receive with the headerless stream mode
1
1
Receive with the protokol of the received packet
Table 5–21: Reception protocol
REG25: Special Mode Settings 2
[default value: 40H]
Bit 7 – 3: reserved
•
The FDL01TU does not use this register. Keep the default value as it is.
Bit 2: Group address settings
0
Normal group address (240 to 254)(default value)
1
Extended group address (1000 to 1023)
Table 5–29: Group address setting
Bit 1: Address response
0
No response the address when the link is connected or disconnected
(default value)
1
Response the destination address when the link is connected or
disconnected.
Table 5–29: Address response
Содержание FDL01TU
Страница 14: ......
Страница 15: ...1 1 SECTION 1 INTRODUCTION ...
Страница 19: ...5 2 SECTION 2 SYSTEM INSTALLATION ...
Страница 25: ...11 3 SECTION 3 SYSTEM OPERATION ...
Страница 34: ...20 ...
Страница 35: ...21 4 SECTION 4 FUNCTION CONTROL METHODS ...
Страница 41: ...27 5 SECTION 5 MEMORY REGISTER DESCRIPTION ...
Страница 56: ...42 ...
Страница 57: ...43 6 SECTION 6 COMMAND SET DESCRIPTION ...
Страница 76: ...62 ...
Страница 77: ...Futaba Corporation Rev 020323 01 7 APPENDIX 7 SECTION ...
Страница 82: ...68 7 4 Dimensions 7 4 1 FDL01TU 7 4 2 Communication Cable ...