v
to the equipment being controlled, or to anything in the area in which
such equipment is located. All integrated control systems should be
designed for “fail-safe” operation so that a temporary or permanent
loss of signal will not endanger any person, critical process, or
equipment (refer to the beginning of the safety section for further
explanation). The system design should ensure that the equipment
being controlled will default to its safest state in the event of signal
loss.
The FDL01TU modem contains no user serviceable parts. If the unit
requires service, contact your sales representative or local branch of
Futaba Corporation per instructions the section titled
How To
Obtain Help
. Do not disassemble or attempt to repair the FDL01TU
yourself. Doing so could void your warranty and may void the user’s
authority to operate the device.
Contact Futaba before using the FDL01TU modem in safety critical
applications such as medical equipment, aircraft, hazardous materials
handling, etc.
II.II
Installation Safety Hazards and Notes
When mounting the FDL01TU modem, use M2 (ISO) screws that
project 2 to 3 mm into the modem. Screws that project further into
the modem (3.5mm MAX) may permanently damage the internal
components and/or cause the FDL01TU modem to malfunction.
Use only the proper regulated DC voltage supplied to the FDL01TU
modem. Use of any other voltage may permanently damage the
modem and/or cause the modem to malfunction and create a shock or
fire hazard.
Be certain that all AC power outlets used the power adapters have
been properly installed, grounded, and fused. An electrical shock
hazard may exist if this unit is powered by a faulty power outlet or
source. If such a situation is discovered, immediately discontinue use
until the power source and outlet have been properly installed,
grounded, and fused by an electrician or other authorized person.
Be sure to wire the power and serial connections correctly. Incorrect
wiring can damage the system, cause it to malfunction and/or create
a shock and fire hazard.
Ensure that the FDL01TU modem power and the power to the
equipment to be controlled is turned off before connecting or
disconnecting the cable between them. This will help prevent
Содержание FDL01TU
Страница 14: ......
Страница 15: ...1 1 SECTION 1 INTRODUCTION ...
Страница 19: ...5 2 SECTION 2 SYSTEM INSTALLATION ...
Страница 25: ...11 3 SECTION 3 SYSTEM OPERATION ...
Страница 34: ...20 ...
Страница 35: ...21 4 SECTION 4 FUNCTION CONTROL METHODS ...
Страница 41: ...27 5 SECTION 5 MEMORY REGISTER DESCRIPTION ...
Страница 56: ...42 ...
Страница 57: ...43 6 SECTION 6 COMMAND SET DESCRIPTION ...
Страница 76: ...62 ...
Страница 77: ...Futaba Corporation Rev 020323 01 7 APPENDIX 7 SECTION ...
Страница 82: ...68 7 4 Dimensions 7 4 1 FDL01TU 7 4 2 Communication Cable ...