24
4.3
Terminal Software Setup for Memory Register Control
Communication or terminal software is necessary to set the
memory registers
. Nearly any
PC communication software can be used. Launch the communication software and set the
terminal’s communication parameters as shown below. Refer to your specific
communication software instructions how to set these parameters.
bit rate: 9600 bps
data length: 8 bits
stop bits: 1 bit
parity bit: none
flow control: none
local echo: yes
terminator: carriage line feed
4.4
Memory Register Setting
Memory registers
set the operation mode and communication parameters of the modem
and retain them in memory. All of the settings of the modem are made by these
memory
registers
.
Since the
memory register
is based on rewritable non volatile memories, these memories
can be readily rewritten by external terminal equipment such as PC and their contents will
be kept even after the power is turned off. This non volatile memory can be rewritten about
1 million times.
4.4.1 Memory Register Referencing and Setting
Memory registers
are referenced and set with the
REG command
. (For more information,
refer to
REG
section at p.43
C
OMMAND
S
ET
D
ESCRIPTION
)
Example procedure:
1. To view the current value of register 00, enter:
@
REG00
CR/LF
2. Modem responds with 00H
CR/LF
(
REG00
is assumed to be 00H in this case and
varies in each setting case)
3. To set register
REG00
to 0FH, enter:
@
REG00:0FH
CR/LF
4. Modem responds with “P0”
CR/LF
5. Enter “
@
RST
CR/LF
” or cycle the modem power, to activate new values
@
= command header (specify following characters are command)
CR/LF
=
Terminator (carriage line feed)
When rewriting the modem’s
memory registers
, do not turn the
modem’s power off until the modem returns “P0”
response
. If the
power is interrupted before “P0” is returned, the memory contents
may be lost or corrupted and the modem operation will be
unpredictable.
CAUTION
Содержание FDL01TU
Страница 14: ......
Страница 15: ...1 1 SECTION 1 INTRODUCTION ...
Страница 19: ...5 2 SECTION 2 SYSTEM INSTALLATION ...
Страница 25: ...11 3 SECTION 3 SYSTEM OPERATION ...
Страница 34: ...20 ...
Страница 35: ...21 4 SECTION 4 FUNCTION CONTROL METHODS ...
Страница 41: ...27 5 SECTION 5 MEMORY REGISTER DESCRIPTION ...
Страница 56: ...42 ...
Страница 57: ...43 6 SECTION 6 COMMAND SET DESCRIPTION ...
Страница 76: ...62 ...
Страница 77: ...Futaba Corporation Rev 020323 01 7 APPENDIX 7 SECTION ...
Страница 82: ...68 7 4 Dimensions 7 4 1 FDL01TU 7 4 2 Communication Cable ...