SMARTSPEED and SMARTSPEED LITE Advanced Protocol Guide
© 2010 Fusion Sport International
30
USER OPTIONS
1.
Period:
the total time for the test over which sampling will occur
2.
Sampling Period:
determines the sub-test periods for which variables are calculated. For example, if user
sets a sampling period of 5 seconds, summary data will be provided for each 5 seconds segment during the
test. PLEASE NOTE – the sampling period must be set when user creates a new protocol (see picture to the
right)
3.
Mat sensitivity –
) the system can be set to ignore a false tap signal caused by an athlete making a temporary
release on the switch (1% = 10ms)
4.
Formula –
pressing this button displays the formulae used in the tapping calculations
RESULTS
ITEM
DESCRIPTION
Index
Sampling index
Taps
Taps counts in sampling period
FT
Total flight time
FT. avg.
Average flight time
CT
Total contact time
CT. avg.
Average contact time
Tap. Freq.
Tapping frequency
Tap. Coef.
Tapping coefficient
Mat sensitivity adjustment
Adjust mat sensitivity to ignore
false signals
Sampling Period
The entire tapping period will
be spitted into standard
sampling period and the
tapping information will be
examined. Sampling period
can be configured when user
create new tapping sub-
protocol.
Formula
Tapping formula used in the
test.
Period
The total time for the test.