SMARTSPEED and SMARTSPEED LITE Advanced Protocol Guide
© 2010 Fusion Sport International
26
1.
Start Type:
allows the user to configure the start type for the session –
a.
Auto (default): timing starts when the athlete in each lane breaks the first gate
b.
Mat/Switch up – timing starts when the athlete lifts their hand/foot OFF the start mat or hand start
pad (note – a start pad or switch must be connected to the start gate)
c.
Mat/Switch down – timing starts when the athlete steps ON to the start mat or starts switch
d.
In beam/mat start – the athlete stands in the beam, or presses down on the start pad, and after 3
seconds the start gate becomes activated (light turns solid green). Timing starts when the athlete
leaves the beam or when their hand comes off the start pad.
2.
Algorythm ON/OFF –
allows you to turn off SMARTSPEED’s Error Correction Processing function
3.
Gate Rearm delay
– allows you to control when the gate will rearm after it is broken. This is especially useful
when you have multiple runners on he track, but only want to measure the first runner.
4.
Mat sensitivity –
when using a mat start (with hand start pad or jump mat) the system can be set to ignore a
false start signal caused by an athlete making a temporary release on the switch (1% = 10ms)
5.
Alignment test –
when using a mat start, pressing this button allows you to test the alignment of the
photocell in between tests.
RESULTS
ITEM
DESCRIPTION
5-yd
5-yard individual split time
10-yd
10-yard individual split time
Total
Lap time/Total Time