SP - 1
E1318S01F
SPECIFICATIONS OF THE COLOR SCANNING SONAR
FSV-24
1
GENERAL
1.1
Scanning method
Continuous scanning beam forming
1.2
Frequency
24 kHz
1.3
Range, TX cycle and Pulse-length
Basic Range
Range (m)
TX cycle
Pulse-length
(m)
Offcenter ‘ON’
Offcenter ‘OFF’
(sec)
(msec)
60
0-60
0-96
0.40-0.80
0.5-1.5
100
0-100
0-160
0.40-0.80
0.5-2.5
150
0-150
0-240
0.54-0.80
0.5-3.8
200
0-200
0-320
0.71-0.91
0.5-5.0
300
0-300
0-480
1.05-1.25
0.8-7.5
400
0-400
0-640
1.35-1.55
1.0-10
500
0-500
0-800
1.61-1.81
1.3-13
600
0-600
0-960
1.86-2.06
1.5-15
800
0-800
0-1280
2.25-2.45
2.0-20
1000
0-1000
0-1600
2.57-2.77
2.5-25
1200
0-1200
0-1920
2.79-3.02
3.0-30
1600
0-1600
0-2560
3.40-3.93
4.0-40
2000
0-2000
0-3200
4.25-4.83
5.0-50
2500
0-2500
0-4000
5.36-5.97
6.3-63
3000
0-3000
0-4800
6.38-7.10
7.5-75
3500
0-3500
0-5000
7.48-7.68
8.8-88
4000
0-4000
0-5000
8.50-8.70
10-100
5000
0-5000
0-5000
8.50-8.70
10-100
1.4
Audio Search
30°, 60°, 90°, 180°, 330° selectable
1.5
Audio Output
1.1 W
1.6
Audio Frequency
1.0 kHz
2
DISPLAY UNIT
2.1
Display Tube
PPI display on 21-inch high-resolution color CRT (for separate type),
1280 (H) x 1024 (V) dots
2.2
Color
32 colors (sonar picture), 16 colors (echo sounder), 4 colors (marks)
2.3
Orientation
Head-up, North-up*, True-motion* and Course-up*
2.4
Presentation Mode Horizontal scan
Combination of Horizontal scan and Vertical-scan 1 or 2
Combination of Horizontal scan and Echo sounder 1 or 2
Combination of Horizontal scan and Vertical-scan + Echo sounder
Содержание FSV-24
Страница 1: ...COLOR SCANNING SONAR FSV 24 ...
Страница 12: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 126: ...This page is intentionally left blank ...
Страница 144: ...This page is intentionally left blank ...
Страница 162: ...This page is intentionally left blank ...
Страница 170: ...This page is intentionally left blank ...