10. MAINTENANCE, TROUBLESHOOTING
10-11
10.10.5 Rx test (For service technician)
This test inputs dummy data to each board and each board outputs a test
pattern (32 color). Select RX TEST at the TEST menu and press the [MENU] key.
Select the board to test with the [MODE] key, in the sequence shown below.
DUAL TEST
IFES TEST
History display
COR TEST
BMFTEST
ADC TEST
Echo sounder display
SCAN-H TEST
Horizontal display
SCAN-H&V TEST
Horizontal display
Vertical display
Horizontal combination dislpay
Horizontal combination display
Horizontal combination dislpay
<<CHECKING RX >>
PRESS MENU KEY TO QUIT TEST MODE.
MODE : CHANGE DISP MODE.
This message appears while the Rx test is
being conducted.
Figure 10-7 Rx test sequence, Rx test message
10.10.6 Noise test (For service technician)
This test measures noise level. Select NOISE TEST at the TEST menu and
press the [MENU] key. The following message appears on the display while the
test is being conducted. Use the [GAIN] control to adjust noise level to medium.
<< NOISE TEST >>
PRESS MENU KEY TO QUIT TEST MODE.
ADJUST NOISE LEVEL TO MEDIUM BY GAIN KNOB.
Figure 10-8 Noise test message