3. INITIAL SETTINGS
3-18
4. Select the [OK] to close the menu.
Note:
For the heaving feature, set the SC-30/50/110 Satellite Compass output as fol-
lows. Refer to respective operator’s manual for setting details.
• Sentence: ATT (GPatt), HVE(GPhve)
• Baud rate: 38400 bps
• Cycle: 25 ms
• Format (SC-50/110 only): IEC Ed.1
3.6.2
Stabilization for external sounder transducer
Set the stabilization menu for external system transducers when [External sounder] is
set [On].
1. Move the cursor onto the sub monitor and right-click on the screen.
The setting menu for external sounder appears.
2. Select [Stabilization] from the list on menu.
The [Stabilization] menu appears.
3. Set the stabilization parameters refer to step 3 on section 3.6.1.
FCV-38[ver 0252473-xx.xx]
Содержание FCV-38
Страница 8: ...EQUIPMENT LISTS vi This page is intentionally left blank ...
Страница 58: ...3 INITIAL SETTINGS 3 24 This page is intentionally left blank ...
Страница 66: ...D 1 9 Sep 2019 H MAKI ...
Страница 67: ...D 2 3 Aug 2020 H MAKI ...
Страница 68: ...D 3 3 Oct 2019 H MAKI ...
Страница 69: ...D 4 26 Sep 2019 H MAKI ...
Страница 70: ...D 5 14 Jun 2018 H MAKI ...
Страница 71: ...D 6 14 Jun 2018 H MAKI ...
Страница 72: ...D 7 14 Jun 2018 H MAKI ...
Страница 73: ...D 8 Jun 10 05 ...
Страница 74: ...D 9 ...
Страница 75: ...Oct 22 07 R Esumi D 10 ...
Страница 76: ...D 11 9 Oct 2019 H MAKI ...
Страница 77: ...D 12 9 Oct 2019 H MAKI ...
Страница 78: ...D 13 11 Mar 2010 Y NISHIYAMA ...
Страница 79: ...D 14 15 Apr 2020 H MAKI ...