2. WIRING
2-40
(Termination resistor ON)
• When setting the starting/ending terminal for the multipoint, or the multipoint is not
connected (CH1 to 4).
(Terminal resistor OFF)
• When setting the terminal other than starting/ending for the multipoint (CH1 to 4).
Jumper block J14
Connector J4 (CH1)
1-2
SHORT
Termination resistor: ON (default setting)
2-3
OPEN
1-2
OPEN
Termination resistor: OFF
2-3
SHORT
Jumper block J15
Connector J5 (CH2)
1-2
SHORT
Termination resistor: ON (default setting)
2-3
OPEN
1-2
OPEN
Termination resistor: OFF
2-3
SHORT
Jumper block J16
Connector J6 (CH3)
1-2
SHORT
Termination resistor: ON (default setting)
2-3
OPEN
1-2
OPEN
Termination resistor: OFF
2-3
SHORT
Jumper block J17
Connector J7 (CH4)
1-2
SHORT
Termination resistor: ON (default setting)
2-3
OPEN
1-2
OPEN
Termination resistor: OFF
2-3
SHORT