2. WIRING
2-7
ricate the power cable as below. For the power cable, use DPYC-2.5 (Japan Industry
Standard) cable or the equivalent.
Note:
For AC: Pass the AC line through a double-contact breaker (shipyard supply)
2.3.1
Fabricating the power cable
1. Cut armor of the cable by 40 mm.
2. Cut vinyl sheath by 35 mm.
3. Remove insulation of wires by about 10 mm. Fix crimp-on lugs to the cores.
4. Scrape off paint of the armor by 40 mm.
5. Cover the end of armor with vinyl tape.
Connection of cables
The power cable is connected to the terminal board on the rear panel. Other cables
are connected to the printed circuit board 03P9342.
40 mm: Scrape off paint.
Taping
(a)
(b)
(d)
Armor
35 mm
10 mm
(c)
Approx. 40 mm
DPYC-2.5
Vinyl sheath