6. MAINTENANCE, TROUBLESHOOTING
6-2
6.2
Consumable Parts
6.2.1
Fuse replacement
The fuse in the Display Unit, Transceiver Unit, Distributor Unit and Rate-of-Turn Gyro
protects those units from overvoltage. If you cannot turn on the power, have a techni-
cian check if the fuse inside the Display Unit has blown. If the fuse has blown, find the
cause before replacing the fuse. If the fuse blows again, contact your dealer. Use the
correct fuse.
6.2.2
Product life
Unit
Fuse
Rating
Type
Code No.
Qty
Remarks
Display Unit
2A
FGMB 2A
AC125V PBF
000-157-479-10
1
Inside unit
Transceiver
Unit
3A
FGB01 3A
AC250V PBF
000-155-841-10
2
Inside unit
Distributor
Unit
5A
FGB01 5A
AC250V PBF
000-155-840-10
2
Inside unit
Rate-of-turn
Gyro
2A
FGB01 2A
AC250V PBF
000-155-829-10
1
Inside unit
Unit
Lifespan (Hrs)
Replacement Part
DS-600 Backlight
30,000 Hrs (55°C)
Panel assy.: DS-600
(001-098-070-00)
DS-340 Fiber Optic Gyro
17,520 Hrs (55°C)
Model: HOFG-1H (VER4.0)
(000-151-796-01)
WARNING
Use the correct fuse.
A wrong fuse can damage the equipment
or cause fire.