Page
8
Operation and Troubleshooting
Electronic Control Input Connections:
Optional Interface boards provide electrical
isolation between the input signal and the brushless DC motor control circuitry, and are
recommended for motion control applications requiring electronic control of motor speed,
rotational direction, deceleration, and braking.
Electronic Speed Control (optional):
Motor speed can be controlled with a 0 to +10 VDC
isolated signal with 0.1 mA current capability in lieu of the manual speed potentiometer. This
speed control input should be connected to terminal S2 on the control board. The common
side of the signal must also be isolated and connected to terminal S1 on the main control
board.
PLC Logic Signal Control of Braking, Direction of Rotation, and Deceleration:
On the furnace, motor braking (or disable), direction of rotation and deceleration is controlled
using optically isolated logic signals from the PLC programmable controller.
WARNING
Never rely on logic circuitry as a means of disabling the motor or control. To prevent unsuspected
mechanical motion and potential injury, the 115 VAC power should always be disconnected
whenever logic circuits or the driven equipment are serviced.
Exercise extreme caution when using Programmable Logic Controllers (PLCs). Although the
output modules are optically isolated output modules, their output commons may be
connected to other circuitry either within or connected to the PLC. In such cases, the PLC
outputs should be isolated from the control board, by a relay or by an electronic isolation
module, to prevent damage to the PLC or the ABL Control.
When a Programmable Controller with a relay output module is not available, AC or DC
outputs from the PLC can be used to drive separate relay coils. See PLC user's manual for
application information. See Figure 7 to determine how to connect relay contacts to the
ABL-3911C.
Figure 8 - Connection to Model 3984 Isolation Interface
Signal Isolation Using the Bodine Model 3984 Interface Module:
Follow the installation
instructions provided with the module to isolate the input signals between the control
electronics and the ABL Control. See Figure 8 for connections.
Содержание LA-309
Страница 5: ...10 004 676 110000 v WARRANTY Warranty goes here ...
Страница 6: ...vi LA 309 Owner s Manual ...
Страница 12: ...Contents xii LA 309 Owner s Manual ...
Страница 20: ...Section 1 1 8 LA 309 Owner s Manual ...
Страница 68: ...Section 3 3 28 LA 309 Owner s Manual ...
Страница 70: ...Section 4 4 2 LA 309 Owner s Manual ...
Страница 72: ...Section 4 4 4 LA 309 Owner s Manual ...
Страница 98: ...Section 5 5 2 LA 309 Owner s Manual ...
Страница 100: ...Section 5 5 4 LA 309 Owner s Manual ...
Страница 106: ...Section 5 5 10 LA 309 Owner s Manual ...
Страница 108: ...Section 5 5 12 LA 309 Owner s Manual ...
Страница 110: ...Section 5 5 14 LA 309 Owner s Manual ...
Страница 112: ...Section 6 6 2 LA 309 Owner s Manual ...
Страница 114: ......
Страница 115: ......
Страница 126: ...Section 7 1 Fiberfrax Cements MSDS 042006 Owner s Manual ...
Страница 139: ...MSDS 2 Fiberfrax Duraboard MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 140: ...Section 7 2 Fiberfrax Duraboard MSDS 042006 Owner s Manual ...
Страница 153: ...MSDS 3 Fiberfrax Fibers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 154: ...Section 7 3 Fiberfrax Fibers MSDS 042006 Owner s Manual ...
Страница 167: ...MSDS 4 Fiberfrax Papers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 168: ...Section 7 4 Fiberfrax Papers MSDS 042006 Owner s Manual ...
Страница 181: ...MSDS 5 Magnaform MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Страница 182: ...Section 7 5 Magnaform MSDS 050406 Owner s Manual ...
Страница 183: ......
Страница 184: ......
Страница 185: ...Section 7 6 RTU Silicone Red Hi Temp 042006 Owner s Manual ...
Страница 186: ...MSDS 6 RTU Silicone Red Hi Temp 042006 MATERIAL SAFETY DATA SHEETS ...
Страница 189: ...Section 7 7 Kaowool Insulation MSDS 050406 Owner s Manual ...
Страница 190: ...MSDS 7 Kaowool Insulation MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Страница 201: ...Material Safety Data Sheets 7 15 Notes ...
Страница 202: ...Section 7 7 16 Owner s Manual ...
Страница 203: ...8 1 Section 8 APPENDIX A 8 1 TEC10 INTERFACE MODULE CALIBRATION 8 2 675 110001 FURNACE DRIVE MOTOR AND CONTROL ...
Страница 204: ...Section 8 Owner s Manual ...
Страница 206: ...Section 8 Owner s Manual ...
Страница 212: ...iv Operation and Troubleshooting ...
Страница 214: ...vi Operation and Troubleshooting ...
Страница 224: ...Page 10 Operation and Troubleshooting ...
Страница 231: ...9 1 Section 9 APPENDIX B 9 1 EC913 CALIBRATION REPORT 9 2 SERIES EC900 OXYGEN ANALYZERS ...
Страница 232: ...Section 8 Owner s Manual ...
Страница 233: ......
Страница 234: ...Section 8 Owner s Manual ...
Страница 276: ...EC900 Series Operation Manual V 4 1 www systechillinois com Page 39 Appendix 1 Drawing Number B900 176 ...
Страница 277: ...EC900 Series Operation Manual V 4 1 www systechillinois com Page 40 Appendix 2 Drawing Number B 920 043 ...
Страница 278: ...EC900 Series Operation Manual V 4 1 www systechillinois com Page 41 Appendix 3 Drawing Number B 900 180 ...
Страница 279: ...Section 8 Owner s Manual ...
Страница 281: ...MSDS MATERIAL SAFETY DATA SHEETS ...
Страница 282: ...16 Notes ...