8 Defining network paths (LAN)
works defined via VLAN IDs, which are to be assigned to the uplink set
defined in the previous step.
8. Enter the meaningful name of the network to be used by the uplink set as
well as the unique VLAN ID of the network within the shared uplink set.
The networks on an uplink set must have different VLAN IDs. In con-
trast, however, two networks on two different uplink sets can use the
same VLAN ID. These networks are still completely separate from one
another.
9. Optional :
l
Specificy a native VLAN network. All packages that do not contain a
VLAN ID will be allowed through this connection.
l
Select a network as service VLAN.
10. Click
Add
, the virtual LAN network is added to the table below.
11. Define any other required networks that are to use the port group, and
confirm each of these with
Add
.
12. You can also define a network as a native VLAN in the table ret-
rospectively. To do this, select the checkbox in the corresponding row
under
Native VLAN
in the table.
13. You can also change the VLAN ID of a network in the table ret-
rospectively. To do this, click in the corresponding row under
VLAN Id
in
the table and edit the VLAN ID.
14. You can also define a network as a service VLAN in the table ret-
rospectively. To do this, select the checkbox in the corresponding row
under
Service VLAN
in the table.
15. You can also delete VLAN networks from the list. To do this, select one
of the VLAN networks in the table and click
Delete.
16. When you have defined all the networks you need, click
Finish
to con-
firm your entries. The networks added to the table are created with the
configured uplink set.
The new defined VLAN networks are added to the tables on the
Graphic
and
Details
tabs.
284
ServerView Virtual-IO Manager
Содержание ServerView Virtual-IO Manager V3.1
Страница 10: ...10 ServerView Virtual IO Manager ...
Страница 56: ...56 ServerView Virtual IO Manager ...
Страница 255: ...Figure 74 VIOM specific log file ServerView Virtual IO Manager 255 6 3 Logging the actions using VIOM ...
Страница 276: ...276 ServerView Virtual IO Manager ...
Страница 300: ...300 ServerView Virtual IO Manager ...
Страница 302: ...302 ServerView Virtual IO Manager ...
Страница 312: ...312 ServerView Virtual IO Manager ...
Страница 330: ...330 ServerView Virtual IO Manager ...
Страница 352: ...352 ServerView Virtual IO Manager ...
Страница 362: ...362 ServerView Virtual IO Manager ...