![Fujitsu ServerView Virtual-IO Manager V3.1 Скачать руководство пользователя страница 279](http://html.mh-extra.com/html/fujitsu/serverview-virtual-io-manager-v3-1/serverview-virtual-io-manager-v3-1_user-manual_121391279.webp)
out what other entries you need to make during the further course of
the wizard, see section
"Defining a dedicated service network" on
page 285
.
You can view the configurations made on the
Graphic
and
Details
tabs.
8.1.1
Defining an internal network
If server blades only need to communicate with each other and, for security
reasons, there must be no connection to an external network, then you con-
figure an internal network without a connection to an uplink. In this case, we
are dealing with internal IBP connections.
When defining the server profiles and assigning these profiles to the server
blade slots, you specify which server blades are to be connected via which
LAN ports via an internal network (see chapter
"Defining and assigning
server profiles" on page 289
).
To define an internal network, follow the steps below:
1. Click on the
Ext. LAN Connections
tab in in the work area on the left.
2. Start the
Create network
wizard by:
l
clicking
New
on the
Graphic
or
Details
tabs
l
selecting
New Uplink Set
in the context menu of an uplink set.
The
Create network
wizard is launched.
3. In the first step of the
Create network
wizard, select
Internal network
and confirm your entry by clicking
Next
. The second step of the
Create
network
wizard opens.
4. Enter the required name for the internal network in
Name of network
.
5. Confirm this by clicking
Finish
. The internal network is configured with
the specified name.
You cannot edit an internal network. To find out how to delete an internal net-
work, see
"Deleting networks" on page 286
".
ServerView Virtual-IO Manager
279
8.1 Defining an uplink set
Содержание ServerView Virtual-IO Manager V3.1
Страница 10: ...10 ServerView Virtual IO Manager ...
Страница 56: ...56 ServerView Virtual IO Manager ...
Страница 255: ...Figure 74 VIOM specific log file ServerView Virtual IO Manager 255 6 3 Logging the actions using VIOM ...
Страница 276: ...276 ServerView Virtual IO Manager ...
Страница 300: ...300 ServerView Virtual IO Manager ...
Страница 302: ...302 ServerView Virtual IO Manager ...
Страница 312: ...312 ServerView Virtual IO Manager ...
Страница 330: ...330 ServerView Virtual IO Manager ...
Страница 352: ...352 ServerView Virtual IO Manager ...
Страница 362: ...362 ServerView Virtual IO Manager ...