Edit Properties step for dedicated service networks
Figure 35: Create Network wizard (second step)
Name of uplink set
Name of uplink set. In the case of a single network, the network auto-
matically has the same name.
Activate Port Backup
Switch to a backup port if an error occurs in the active port. The port
backup function is only available if at least one backup port is con-
figured.
By default,
Activate Port Backup
is selected.
Linkdown propagation
Send a linkdown event if both the active ports and the backup ports fail.
The linkdown event triggers a failover process on the server blade if con-
figured accordingly.
ServerView Virtual-IO Manager
169
5.4 Wizards