-
When installing using a legacy boot
"legacy"
-
When installing using UEFI
"uefi"
Server Blade VLAN Data
-
Section Name
Enter [ServerNet] as the section name.
-
Section Header
operation
Enter the desired operation for the current line. Enter a hyphen ("-") to skip this line.
server_name
Enter the server name (the value of "server_name" in the [Server] section).
nic_no
This is the index number of the server blade's network interface. Enter a number between 1 and 12.
vlan_id (optional)
Enter the VLAN ID and tag type ("/T" or "/U") to be assigned to the LAN switch blade port connected to this server's network
interface.
Enter a VLAN ID followed by tag types. To specify multiple VLAN IDs, separate each set of VLAN settings using semicolons
(";"). Both tagged ("/T") and untagged ("/U") VLAN IDs can be used together, but only one untagged ("/U") type is allowed.
Example
10/U
10/U;20/T;30/T
10/T;20/T
Note
If a hyphen ("-") is entered, VLAN settings will not be performed.
Use the following NIC indexes to specify LAN expansion cards (if any was mounted).
-
PRIMERGY BX600 Servers
7, 8
-
PRIMERGY BX900/BX400 Servers
5 to 12
This section will be ignored for PRIMERGY BX900/BX400 LAN switch blades operating in IBP mode.
For a LAN switch blade PY CB DCB SW 10Gb 18/6/6, this section will be ignored for internal ports for which an Automatic
Migration of Port Profile (AMPP) has been configured.
- 369 -