Upgrade and Maintenance Manual
TX120
S3
Basic software procedures
I
Administrator permission required: If you are prompted for an
administrator password or confirmation, type the password or
provide confirmation.
Ê
To temporarily disable BitLocker, click
Turn Off BitLocker
, and then click
Disable BitLocker Drive Encryption
.
I
In order to determine which features are accessible through the
BitLocker setup wizard, modify the BitLocker Group Policy settings.
For further information on how to disable BitLocker drive encryption,
please refer to the Microsoft Knowledge Base.
Fujitsu service partners will find additional information (also available
in Japanese) on the Fujitsu Extranet web pages.
5.1.2
Disabling SVOM boot watchdog functionality
The ServerView Operations Manager boot watchdog determines whether the
server boots within a preset time frame. If the watchdog timer expires, the
system will automatically reboot.
5.1.2.1
Viewing boot watchdog settings
To view boot watchdog settings in ServerView Operations Manager, proceed as
follows:
Ê
In ServerView Operations Manager
Single System View
select
Maintenance
from the
Information / Operation
menu.
Ê
Under
ASR&R
select the
Watchdog
tab to obtain detailed information about
the current watchdog status, time out intervals and actions that are triggered
if watchdog timeouts are exceeded.
I
For more detailed information, refer to the "ServerView Operations
Manager - Server Management" user guide.
5.1.2.2
Configuring boot watchdog settings
If the system is to be started from removable boot media for firmware upgrade
purposes, the Boot watchdog needs to be disabled before starting maintenance
task. Otherwise, the Boot watchdog might initiate a system reboot before the
flash process is complete.
Содержание PRIMERGY TX120 S3
Страница 6: ...Upgrade and Maintenance Manual TX120 S3 ...
Страница 8: ...Upgrade and Maintenance Manual TX120 S3 Version history ...
Страница 22: ...Upgrade and Maintenance Manual TX120 S3 Contents ...
Страница 26: ...26 Upgrade and Maintenance Manual TX120 S3 Introduction ...
Страница 48: ...48 Upgrade and Maintenance Manual TX120 S3 Important information ...
Страница 110: ...110 Upgrade and Maintenance Manual TX120 S3 Basic software procedures ...
Страница 191: ...TX120 S3 Upgrade and Maintenance Manual 191 Expansion cards and backup units Figure 87 Installed BBU in BBU holder ...
Страница 244: ...244 Upgrade and Maintenance Manual TX120 S3 Main memory ...
Страница 362: ...362 Upgrade and Maintenance Manual TX120 S3 System board and components ...
Страница 418: ...418 Upgrade and Maintenance Manual TX120 S3 Cables Figure 276 Installed BBU in BBU holder ...
Страница 422: ...422 Upgrade and Maintenance Manual TX120 S3 Cables ...