Upgrade and Maintenance Manual
TX120
S3
Accessible drives
12.3 Backup drive
12.3.1 Installing backup drive
12.3.1.1 Required tools
●
Preliminary and concluding steps: toolless
●
Removing accessible drives:
– Phillips PH2 / (+) No. 2 screw driver
12.3.1.2 Preliminary steps
Before installing an accessible drive, perform the following steps:
Ê
Disable BitLocker functionality as described in section
"Disabling BitLocker
functionality" on page 79
.
Ê
Shut down the server as described in section
"Shutting down the server" on
page 58
.
Ê
Disconnect the AC power cord from the system.
Ê
Remove the server cover as described in section
"Opening the server" on
page 61
.
Upgrade and Repair Units (URU)
Average task duration: 10 minutes
Содержание PRIMERGY TX120 S3
Страница 6: ...Upgrade and Maintenance Manual TX120 S3 ...
Страница 8: ...Upgrade and Maintenance Manual TX120 S3 Version history ...
Страница 22: ...Upgrade and Maintenance Manual TX120 S3 Contents ...
Страница 26: ...26 Upgrade and Maintenance Manual TX120 S3 Introduction ...
Страница 48: ...48 Upgrade and Maintenance Manual TX120 S3 Important information ...
Страница 110: ...110 Upgrade and Maintenance Manual TX120 S3 Basic software procedures ...
Страница 191: ...TX120 S3 Upgrade and Maintenance Manual 191 Expansion cards and backup units Figure 87 Installed BBU in BBU holder ...
Страница 244: ...244 Upgrade and Maintenance Manual TX120 S3 Main memory ...
Страница 362: ...362 Upgrade and Maintenance Manual TX120 S3 System board and components ...
Страница 418: ...418 Upgrade and Maintenance Manual TX120 S3 Cables Figure 276 Installed BBU in BBU holder ...
Страница 422: ...422 Upgrade and Maintenance Manual TX120 S3 Cables ...