C120-E093-04EN
63
6.3 Main Unit Power Control
6.3.4
RCI Settings
RCI setting should only be performed by a certified service engineer. Making any changes to the
setting by the user may cause system malfunction.
RCI setting can be made through "RCI relating settings," in "Machine Administration Menu" of
the System Console Software on the SMC. The following RCI settings can be modified.
l
Display of the RCI network list
Displays the RCI network list.
l
Confirmation of RCI-connected devices
Association of an RCI address and physical units.
l
Initial configuring of the RCI network
The initial configuration of the RCI network can be modified.
l
Increase of RCI device
Reconstruction of the RCI network can be modified.
l
Display and setting of RCI status check timeout time
Displays and sets monitoring time of no-communication-timeouts of RCI network.
l
Maintenance of the RCI-connected file units
Displays guidance of maintenance operations regarding the fans and the power source of the
file units for easy operation.
6.3.5
Setting Power Recovery Mode
The SMC offers the following three alternative modes regarding the power-on operation after a
power recovery following a power failure event. The settings of the power recovery mode are
controlled for each main unit. When the Mode switch of the operator panel is set to the
"MAINTENANCE" mode, the main power will not be powered on upon a power recovery
regardless of the mode setting with any of the followings:
1. Upon power recovery, returns the main unit to the state before the power failure occurred.
(This means the system is powered on activating any partition which was active when the
power failure occurred. If the partition was not powered on when the power failure occurred,
the partition is not powered on.)
2. Upon power recovery, main unit activation is not performed.
3. When power is recovered within the scheduled operation time, partition activation is
performed.
Power recovery mode can be set by using the "apcsset" command on the SMC. For how to use
the "apcsset" command, see "apcsset (1M)," in Appendix A, "Command Reference," in the
"System Console Software User's Guide."
Содержание PRIMEPOWER 800
Страница 1: ...Edition December 2001 PRIMEPOWER1000 800 ...
Страница 5: ...PRIMEPOWER 1000 800 User s Manual C120 E093 04EN ...
Страница 6: ......
Страница 10: ......
Страница 20: ......
Страница 54: ...26 C120 E093 04EN CHAPTER 4 Hardware Overview Figure 4 4 System Board ...
Страница 92: ......
Страница 96: ......
Страница 114: ......
Страница 116: ......
Страница 130: ......
Страница 134: ......
Страница 140: ......
Страница 142: ......
Страница 144: ......