82
C120-E093-04EN
CHAPTER 9 System Management Console (SMC)
4
Enter the root password to shift to single user mode.
5
Insert the data cassette containing the setup data into the DAT unit. Make sure
that the write-protection tab on the data cassette is set to "Write-protected"
beforehand.
6
Enter the command below to execute the restore command.
7
Specify to reconfigure the system components, then reboot the system.
The System Control LAN needs to be re-established by reactivating it after the inactivation
using the "Machine Administration Menu" of the System Console Software. For details on the
re-establishment of the System Control LAN, see "Restoration procedure of system console," in
the Appendix B, "Troubleshooting," in the "System Console Software User's Guide."
8
Restore the monitor log (information automatically stored in the partition
periodically) created by the Machine administration program by using the
"Machine Administration Menu" of System Console Software.
9
If appropriate, check the Auto Power Control schedule and activate the Auto
Power Control.
10
Press the Eject switch on the DAT drive to remove the data cassette.
SMC# /opt/FJSVscsl/bin/scslrestore -t /dev/rmt/0
<Return>
SMC# touch /reconfigure
<Return>
SMC# /usr/sbin/shutdown -g0 -y -i6
<Return>
Содержание PRIMEPOWER 800
Страница 1: ...Edition December 2001 PRIMEPOWER1000 800 ...
Страница 5: ...PRIMEPOWER 1000 800 User s Manual C120 E093 04EN ...
Страница 6: ......
Страница 10: ......
Страница 20: ......
Страница 54: ...26 C120 E093 04EN CHAPTER 4 Hardware Overview Figure 4 4 System Board ...
Страница 92: ......
Страница 96: ......
Страница 114: ......
Страница 116: ......
Страница 130: ......
Страница 134: ......
Страница 140: ......
Страница 142: ......
Страница 144: ......