38
C120-E093-04EN
CHAPTER 5 Main Unit Operator Panel Operation
Table 5.1
lists the meanings of the Mode switch on the operator panel.
*) auto boot: Solaris automatically starts up when main power is turned on.
boot stop: Stops in OBP mode when main power is turned on. Solaris is not activated.
If the OS is activated when Poff (described above) is operated, it starts the shutdown sequence.
Table 5.1 Meanings of the Mode Switch
Function
Mode switch
LOCK
UNLOCK
MAINTENANCE
State definition
Normal operating
state
Maintenance state
(Software)
Maintenance state
(Hardware)
Sending Break recognition
Disabled
Enabled
Enabled
Pon/Poff
(*)
Pon/Poff by the
power switch
Only power-on is
enabled
(auto boot)
Enabled
(boot stop)
Enabled
(boot stop)
Pon/Poff by the
SMC
Enabled
(auto boot)
Enabled
(boot stop)
Enabled
(boot stop)
Pon/Poff by the
facility (RCI)
Enabled
(auto boot)
Enabled
(boot stop)
Disabled
Partition start-up
command (up) by
the panel
Enabled
(auto boot)
Enabled
(boot stop)
Enabled
(boot stop)
Pon/Poff by the
Automatic Power
control
Enabled
(auto boot)
Enabled
(boot stop)
Only power-off is
enabled
Содержание PRIMEPOWER 800
Страница 1: ...Edition December 2001 PRIMEPOWER1000 800 ...
Страница 5: ...PRIMEPOWER 1000 800 User s Manual C120 E093 04EN ...
Страница 6: ......
Страница 10: ......
Страница 20: ......
Страница 54: ...26 C120 E093 04EN CHAPTER 4 Hardware Overview Figure 4 4 System Board ...
Страница 92: ......
Страница 96: ......
Страница 114: ......
Страница 116: ......
Страница 130: ......
Страница 134: ......
Страница 140: ......
Страница 142: ......
Страница 144: ......