72
C120-E093-04EN
CHAPTER 8 Approaches to Troubleshooting
If abnormality is detected while any partition is selected (the cursor points 0 to e), the following
messages are displayed.
If any fault is detected while FEP/XB-DDC symbol is selected (the cursor points to P), the
following messages listed in
Table 8.3
are displayed. If any defective FEP or XB-DDC is
detected, the selected symbol (P) blinks. If a defective FEP or XB-DDC is not detected, no
message will be displayed.
Figure 8.2 FEP/XB-DDC Error Messages
Table 8.2 Partition Error Messages
Display data
Contents
Message details
Panic
Panic occurred in the OS.
After the panic, the OS automatically
restarts.
SB#xx alarm
An alarm was generated at System Board
#xx in the partition.
xx: System Board slot number
SB#xx warning
A warning was generated at System Board
#xx in the partition.
xx: System Board slot number
Displayed message
X
-
Y Y
:
x#FEPnn failed
T H Z
∞
P
C
S
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
Cursor position
Table 8.3 FEP/XB-DDC Error Messages (1/2)
Display data
Contents
Message details
0#FEPnn failed
Indicates a fault FEP. If multiple
fault FEPs were detected, the unit
detected last is indicated.
First numerical value 0 (*):
One or more than one defective FEP is
detected in the cabinet in which the panel
is included (the Base cabinet).
First numeric value 1:
One or more than one defective FEP is
detected in the cabinet in which the panel
is not included (the System Expansion
cabinet).
nn: FEP number
Содержание PRIMEPOWER 800
Страница 1: ...Edition December 2001 PRIMEPOWER1000 800 ...
Страница 5: ...PRIMEPOWER 1000 800 User s Manual C120 E093 04EN ...
Страница 6: ......
Страница 10: ......
Страница 20: ......
Страница 54: ...26 C120 E093 04EN CHAPTER 4 Hardware Overview Figure 4 4 System Board ...
Страница 92: ......
Страница 96: ......
Страница 114: ......
Страница 116: ......
Страница 130: ......
Страница 134: ......
Страница 140: ......
Страница 142: ......
Страница 144: ......