Interface
5-150 C141-E202-01EN
Table 5.29 Ultra DMA data burst timing requirements (2 of 2)
MODE 0
(in ns)
MODE 1
(in ns)
MODE 2
(in ns)
MODE 3
(in ns)
MODE 4
(in ns)
MODE 5
(in ns)
NAME
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX
COMMENT
t
LI
0 150 0 150 0 150 0 100 0 100 0 75
Limited
interlock
time
(*1)
t
MLI
20 20 20 20 20 20
Interlock
time
with
minimum
(*1)
T
UI
0 0 0 0 0 0
Unlimited
interlock
time
(*1)
t
AZ
10 10 10 10 10 10
Maximum
time
allowed
for
output
drivers to release (from asserted or
negated)
t
ZAH
20 20 20 20 20 20
Minimum
delay
time
required
for
output
t
ZAD
0 0 0 0 0 0
Drivers
to
assert
or
negate
(from
released)
t
ENV
20 70 20 70 20 70 20 55 20 55 20 50
Envelope
time
(from
DMACK-
to
STOP and HDMARDY- during
data in burst initiation and from
DMACK to STOP during data out
burst initiation)
t
RFS
75 70 60 60 60 50
Ready-to-final-STROBE
time
(no
STROBE edges shall be sent this
long after negation of DMARDY-)
t
RP
160 125 100 100 100 85 Ready-to-pause
time
(that
recipient shall wait to pause after
negating DMARDY-)
t
IORDYZ
20 20 20 20 20 20
Maximum
time
before
releasing
IORDY
t
ZIORDY
0 0 0 0 0 0
Minimum
time
before
driving
IORDY (*4)
t
ACK
20 20 20 20 20 20
Setup
and
hold
times
for
DMACK- (before assertion or
negation)
t
SS
50 50 50 50 50 50
Time
from
STROBE
edge
to
negation of DMARQ or assertion
of STOP (when sender terminates
a burst)
*1: Except for some instances of t
MLI
that apply to host signals only, the parameters t
UI,
t
MLI
and t
LI
indicate sender-to-recipient or recipient-
to-sender interlocks, i.e., one agent (either sender or recipient) is waiting for the other agent to respond with a signal before
proceeding. t
UI
is an unlimited interlock that has no maximum time value. t
MLI
is a limited time-out that has a defined minimum. t
LI
is a limited time-out that has a defined maximum.
*2: 80-conductor cabling shall be required in order to meet setup (t
DS
, t
CS
) and hold (t
DH
, t
CH
) times in modes greater than 2.
*3: Timing for t
DVS
, t
DVH
, t
CVS
and t
CVH
shall be met for lumped capacitive loads of 15 and 40 pf at the connector where all signals (Data and
STROBE) have the same capacitive load value. Due to reflections on the cable, the measurement of these timings is not valid in a
normally functioning system.
*4: For all modes the parameter t
ZIORDY
may be greater than t
ENV
due to the fact that the host has a pull up on IORDY- giving it a known
state when not actively driven.
*5: The parameters t
DS
, and t
DH
for mode 5 is defined for a recipient at the end of the cable only in a configuration with one device at the
end of the cable.
Note:
All timing measurement switching points (low to high and high to low) shall be taken at 1.5V.
Содержание MHU2100AT
Страница 1: ...C141 E202 01EN MHU2100AT DISK DRIVE PRODUCT MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 8: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 24: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 238: ...This page is intentionally left blank ...
Страница 260: ...This page is intentionally left blank ...
Страница 264: ...This page is intentionally left blank ...
Страница 266: ...This page is intentionally left blank ...
Страница 272: ...This page is intentionally left blank ...
Страница 274: ...This page is intentionally left blank ...
Страница 275: ...MHU2100AT DISK DRIVE PRODUCT MANUAL C141 E202 01EN MHU2100AT DISK DRIVE PRODUCT MANUAL C141 E202 01EN ...
Страница 276: ...This page is intentionally left blank ...
Страница 277: ......
Страница 278: ......