5.6 Timing
C141-E202-01EN 5-147
5.6.2 Multiword data transfer
Figure 5.10 shows the multiword DMA data transfer timing between the device
and the host system.
DMACK-
t
D
DIOR-/DIOW-
t
I
Symbol Timing
parameter Min.
Max.
Unit
t0
Cycle time
120
—
ns
tD
Pulse width of DIOR-/DIOW-
70
—
ns
tE
Data Access time for DIOR-
—
50
ns
tF
Data hold time for DIOR-
5
—
ns
tG
Data setup time for DIOR-/DIOW-
20
—
ns
tH
Data hold time for DIOW-
10
—
ns
tI
DMACK setup time for DIOR-/DIOW-
0
—
ns
t
CS (1:0) Available time for DIOR-/DIOW-
25
—
ns
Figure 5.10 Multiword DMA data transfer timing (mode 2)
Содержание MHU2100AT
Страница 1: ...C141 E202 01EN MHU2100AT DISK DRIVE PRODUCT MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 8: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 24: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 238: ...This page is intentionally left blank ...
Страница 260: ...This page is intentionally left blank ...
Страница 264: ...This page is intentionally left blank ...
Страница 266: ...This page is intentionally left blank ...
Страница 272: ...This page is intentionally left blank ...
Страница 274: ...This page is intentionally left blank ...
Страница 275: ...MHU2100AT DISK DRIVE PRODUCT MANUAL C141 E202 01EN MHU2100AT DISK DRIVE PRODUCT MANUAL C141 E202 01EN ...
Страница 276: ...This page is intentionally left blank ...
Страница 277: ......
Страница 278: ......