1-5. Compressor frequency limitation by outdoor temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
•
Cooling/Dry mode
F zone
38°C
E zone
19°C
D zone
10°C
C zone
B zone
A zone
0°C
-10°C
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOHG18KMTA
A zone
26 rps
B zone
26 rps
C zone
26 rps
D zone
16 rps
E zone
12 rps
F zone
18 rps
AOHG24KMTA
A zone
24 rps
B zone
24 rps
C zone
24 rps
D zone
14 rps
E zone
14 rps
F zone
22 rps