8-3. Current release control
The rotation number of compressor is controlled so that the outdoor unit input current does not ex-
ceeds current limit value set according to the outdoor temperature.
The rotation number of compressor returns according to the operation mode, when the current be-
comes lower than the release value.
¢
Model: AOHG18KMTA
Operation mode
Outdoor temp. (Ta)
Trigger condition Release condition
Cooling
50°C ≤ Ta
4.5 A
4.0 A
46°C ≤ Ta < 50°C
4.5 A
4.0 A
40°C ≤ Ta < 46°C
6.0 A
5.5 A
12°C ≤ Ta < 40°C
9.0 A
8.5 A
2°C ≤ Ta < 12°C
9.0 A
8.5 A
Ta < 2°C
9.0 A
8.5 A
Heating
17°C ≤ Ta
7.0 A
6.5 A
12°C ≤ Ta < 17°C
9.0 A
8.5 A
5°C ≤ Ta < 12°C
11.0 A
10.5 A
Ta < 5°C
13.0 A
12.5 A
¢
Model: AOHG24KMTA
Operation mode
Outdoor temp. (Ta)
Trigger condition Release condition
Cooling
50°C ≤ Ta
7.0 A
6.5 A
46°C ≤ Ta < 50°C
7.0 A
6.5 A
40°C ≤ Ta < 46°C
9.5 A
9.0 A
12°C ≤ Ta < 40°C
12.5 A
12.0 A
2°C ≤ Ta < 12°C
12.5 A
12.0 A
Ta < 2°C
12.5 A
12.0 A
Heating
17°C ≤ Ta
10.5 A
10.0 A
12°C ≤ Ta < 17°C
13.0 A
12.5 A
5°C ≤ Ta < 12°C
14.5 A
14.0 A
Ta < 5°C
15.5 A
15.0 A
8-4. Cooling pressure over-rise protection
→hen the outdoor unit heat exchanger temperature reaches trigger condition below, the compressor
is stopped and trouble display is performed.
Trigger condition
65°C
8-5. Compressor temperature protection
→hen the compressor temperature sensor detects higher than the trigger condition below, the com-
pressor is stopped. →hen the compressor temperature sensor detects the release condition, the pro-
tection is released.
Trigger condition
108°C
Release condition
80°C
(3 minutes after compressor stop)
8-3. Current release control
- (04-28) -
8. Various protections
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание GENERAL AOHG18KMTA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2022 03 11 SR_CH01_AS070EG_01 ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 11 SR_CH02_AS070EG_02 ...
Страница 40: ...7 3 Model AOHG24KMTA 02 24 7 PC board diagrams TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...
Страница 41: ...3 TROUBLESHOOTING 2022 03 25 SR_CH03_AS070EG_01 ...
Страница 44: ......
Страница 103: ...4 CONTROL AND FUNCTIONS 2022 03 25 SR_CH04_AS070EG_01 ...
Страница 105: ...8 8 High temperature and high pressure release control heating mode 04 29 CONTENTS continued ...
Страница 106: ......
Страница 137: ...5 FILED WORKING 2022 03 25 SR_CH05_AS070EG_01 ...