Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

Driver

ƽ

Torque wrench

ƽ

(17mm,22mm,26mm)

Nipper

ƽ

Reamer

ƽ

Hacksaw

ƽ

Pipe cutter

ƽ

Gas leakage detector or

ƽ

soap-and-water solution

Hole core drill

ƽ

Flaring tool

ƽ

Spanner(17,19 and 26mm)

ƽ

Knife

ƽ

Measuring tape

ƽ

Indoor Unit

Place, robust not causing vibration, where the body can be supported sufficiently.

ƽ

Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.

ƽ

Place, possible to drain easily, where piping can be connected with the outdoor unit.

ƽ

Place, where cold air can be spread in  a  room entirely.

ƽ

Place, nearby a power receptacle, with enough space around. (Refer to drawings).

ƽ

Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.

ƽ

In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent

ƽ

lamps in the room are lightened.

Outdoor Unit

Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.

ƽ

Place, possible to bear the unit, where vibration and noise are not increased.

ƽ

Place, where discharged wind and noise do not cause a nuisance to the neighbors.

ƽ

Place, where a distance marked

ƽ

is available as illustrated in the above figure.

Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the

ƽ

corresponding name plate.

Install an exclusive branch circuit of the power.

ƽ

A receptacle shall be set up in  a  distance where the power cable can be
reached. Do not extend the cable by cutting it.

ƽ

Power Source

Preparation

Please be subject to the actual product purchased , the above picture is just for your reference.

Read this manual before installation
Explain sufficiently the operating means to the user according to this manual.

NO.0010519573

Installation Manual of Room Air Conditioner

F

A

C

E

D

Optional parts for piping

Non-adhesive tape

Adhesive tape

Saddle (L.S) with screws

Connecting electric cable

for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Floor fixing dimensions of the

outdoor unit (Unit:mm)

Fixing of outdoor unit

Fix the unit to concrete or block

ƽ

with bolts (10mm) and nuts firmly

and horizontally.

When fitting the unit to wall

ƽ

surface, roof or rooftop, fix

a supporter surely with nails

or wires in consideration of 

earthquake and strong wind.

If vibration may affect the

ƽ

house, fix the unit by attaching a 

vibration-proof mat.

The marks from

to

in the figure are the

parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.

The models adopt HFC free refrigerant R410A

more than
10cm

more than 5cm

more than 10cm

more than 10cm

more than
10cm

more than15cm

more than
60cm

A

G

ƽ

ƽ

106.5

106.5

566

31

7

A

F

C

E

D

G

B

Arrangement of piping
directions

Rear left

Left

Rear
right

Right

Below

G

Attention must be paid to

the rising up of drain hose

Selection of Installation Place