To enable system replication throttling:
1. Under
Target
systems, click the box next to
Throttling
.
The
Replication Throttle
window displays (see
).
Figure 149: System Throttling
2. In the drop-down box, select the units you want to use to specify the constant throttle
(
KB/s
or
MB/s
). To disable system throttling clear the Enable system throttling check
box.
3. In the box, enter the maximum allowed bandwidth. The lowest value you can set is 32
KB/s. The highest value you can set is 125 MB/s.
4. Click
Apply
.
V
CAUTION
!
Do not set the maximum allowed bandwidth to a value that is lower than necessary.
If the maximum allowed bandwidth is set to the lowest value, large replication jobs
may fail.
Source System List
The
Source System
list displays the following information for each source system:
●
Source
- The IP address of the source system that is allowed to send data to the
ETERNUS CS800.
●
Actual Data Received
- The amount of data actually received over the network during
replication or failback.
Содержание ETERNUS CS800 S5
Страница 1: ...Edition June 2014 English ETERNUS CS800 S5 V2 3 1 User Guide ...
Страница 14: ...Contents U41840 J Z125 7 76 ...
Страница 30: ...Environmental Protection Important Information 28 U41840 J Z125 7 76 ...
Страница 48: ...Network Configuration System Description 46 U41840 J Z125 7 76 ...
Страница 80: ...Locating the Serial Number Hardware Description and Basic Operations 78 U41840 J Z125 7 76 ...
Страница 116: ...Further Configurations Installing the ETERNUS CS800 S5 Modules 102 U41840 J Z125 7 76 ...
Страница 149: ...Remote Management The Remote Management Console U41840 J Z125 7 76 135 Figure 84 Remote Management Pages Map ...
Страница 150: ...The Remote Management Console Remote Management 136 U41840 J Z125 7 76 ...
Страница 190: ...AIS Connect Configuration Wizards 176 U41840 J Z125 7 76 ...
Страница 200: ...Current Activity Overview Home Page 186 U41840 J Z125 7 76 ...
Страница 301: ...Configuration System U41840 J Z125 7 76 287 Figure 177 Network Configuration ...
Страница 353: ...Configuration Contacts U41840 J Z125 7 76 339 Figure 211 Primary and Secondary Pages ...
Страница 402: ...Reports Replication 388 U41840 J Z125 7 76 ...
Страница 406: ...Hardware Status 392 U41840 J Z125 7 76 Figure 236 System Board Page ...
Страница 432: ...Activity Log Status 418 U41840 J Z125 7 76 ...
Страница 442: ...Service Tickets Alerts 428 U41840 J Z125 7 76 ...
Страница 462: ...Reboot Shutdown Utilities 448 U41840 J Z125 7 76 ...
Страница 470: ...Common Problems and Solutions Troubleshooting 456 U41840 J Z125 7 76 ...
Страница 496: ...Additional Specifications for Scale Mode System Specifications S5 626 U41840 J Z125 7 76 ...
Страница 634: ...Index 634 U41840 J Z125 7 76 ...